Three-Phase Power Analyzer, Built-in Programming Keyboard, Advanced Version, 96x96 Panel
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Maelezo ya Kiufundi

Energy ManagementPower AnalyzerType WM14 96 “Advanced version”• Protection degree (front): IP65• 2 digital outputs• 16 freely configurable alarms with OR/AND logic linkable with up to 2 digital outputs• RS422/485 serial output (MODBUS-RTU), iFIX SCADAcompatibilityProduct Description• Class 1 (kWh), Class 2 (kvarh)• Accuracy ±0.5 F.S. (current/voltage)• Power Analyzer• Instantaneous variables read-out: 3 DGT• Energies readout: 8+1 DGT• System variables: VLL, VLN, An, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmdmax, var, PF, Hz, ASY• Single phase variables: VLL, VLN, VLN min, VLN max, A, Amin, Amax, Admd, VA, W, Wdmd, Wmax, var, PF, PFmin• Harmonic analysis (FFT) up to the 15thharmonic (cur-rent and voltage)• Four quadrant power measurement• Energy measurements: total and partial kWh and kvarh• Hour counter (5+2 DGT)• TRMS meas. of distorted sine waves (voltages/currents)• Universal power supply: 90 to 260 VAC/DC, 18 to 60 VAC/DC• Front dimensions: 96x96mm• Voltage asymmetry, phase sequence, phase loss controlHow to orderWM14-96AV5 3 H R2 S1 AX3-phase advanced power analyzer with integrated pro- gramming key-pad. Particu- larly recommended for the measurement of the main electrical variables.Housing for panel mounting, with RS485 communication port or pulse and/or alarm outputs.Model Range code SystemPower supplyOutput 1Output 2OptionType SelectionRange codesAV5: 380/660VL-L/1/5(6)AAC VL-N: 185 V to 460 VVL-L: 320 V to 800 VAV6: 120/208VL-L/1/5(6)AAC VL-N: 45 V to 145 VVL-L: 78 V to 250 VSystem3 :1, 2 or 3 phase, balanced/unbalanced load, with or without neutralPower supplyOutput 1R2: 2-relay outputsO2: 2-open collector outputsOutput 2XX: NoneS1: RS485/RS422 portOptionsPhase current: 0.03A to 6ANeutral current: 0.09A to 6AL: 18 to 60 VAC/VDCH: 90 to 260 VAC/VDCAX: advanced functionsInputspecificationsRated inputsSystem type: 3 - phaseCurrent3 (By shunts) Voltage4Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%)1150W-VA-var, FS:230VLN,400VLL AV6: 285W-VA-var, FS:57VLN, 100VLLCurrent 0.25 to 6A: ±(0.5% FS +1DGT)0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current0.25 to 6A: ±(1.5% FS +1DGT)0.09Ato0.25A:±(1.5%FS+7DGT)Phase-phase voltage ±(1.5% FS +1 DGT)Phase-neutral voltage ±(0.5% FS + 1 DGT)Active and Apparent power,0.25 to 6A: ±(1% FS +1DGT)0.03A to 0.25A: ±(1% FS+5DGT)Reactive power 0.25 to 6A: ±(2% FS +1DGT)0.03A to 0.25A: ±(2% FS+5DGT)Active energy Class 1 (start up current: 30mA) Reactive energyClass 2 (start up current: 30mA) Frequency±0.1Hz (48 to 62Hz) Harmonic distortion ±3% F.S. (up to 15th harmonic)(F.S.: 100%)Specifications are subject to change without noticeWM14 96 A DS ENG2305081

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji

Top