Muda wa huduma: Jumatatu hadi Ijumaa 9:00-18:00
VAL-MS 1000DC-PV/2+V - VAL-MS 1000DC-PV/2+V 2800628 PHOENIX CONTACT Surge arrester for 2-pos. isolated 1000 V DC voltage systems, f..
Kipatikana Bidhaa Maarufu

VAL-MS 1000DC-PV/2+V

VAL-MS 1000DC-PV/2+V 2800628 PHOENIX CONTACT Surge arrester for 2-pos. isolated 1000 V DC voltage systems, f..

$0.00USD
4017 kwenye hisa
Vipimo Muhimu
:PV T2
Dokezo:The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Aina:DIN rail module, two-section, divisible
Rangi:jet black RAL 9005
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
PV T2
DokezoThe device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
AinaDIN rail module, two-section, divisible
Rangijet black RAL 9005
Kina65.5 mm
Upana53.4 mm
Urefu≤ 2000 m (amsl (above mean sea level))
Aina ya SPD4 (for Type 2 photovoltaic applications)
Muundo wa SPDVoltage-limiting type
Volti ya nambari970 V AC
Uzi wa skrubuM5
UfikivuAccessible
Aina ya kupachikaDIN rail: 35 mm
Idadi ya milangoOne
Mlalo wa sauti3 Div.
Nyenzo za makaziPA 6.6-FR
Kiwango cha uchafuzi wa mazingira2
Urefu wa kukatwa16 mm
Mbinu ya muunganishoScrew connection
Mshtuko (upasuaji)60g (Half sine/11 ms/3x XYZ)
Kukaza torque4.5 Nm
Njia ya ulinzi(L+) - (L-)
Kiwango cha ulinziIP20 (only when all terminal points are used)
IPE ya mkondo uliobaki≤ 20 µA DC
Tabia ya kushindwa kwa SPDOCM (Open-circuit mode)
Eneo la usakinishajiInside
Imekadiriwa IL ya sasa ya mzigo80 A
Mtetemo (uendeshaji)7.5g (5-500 Hz/2.5 h/XYZ)
Uainishaji wa mtihani wa IECPV T2
Usanidi wa muunganishoY configuration
Muda wa majibu tA(L-) -PE≤ 25 ns
Viwango/vipimoEN 50539-11 2013
Mfumo wa usambazaji wa nguvu1
Muda wa majibu tA(L+) - PE≤ 25 ns
Upinzani wa insulation Riso> 5 GΩ (at 500 V DC)
Sehemu ya msalaba ya kondakta AWG15 ... 2
Volti ya mzunguko wazi UOCSTC≤ 970 V DC
Muda wa majibu tA(L+) - (L-)≤ 25 ns
Kompyuta ya matumizi ya nguvu ya kusubiri≤ 25 mVA
Ure za volteji zilizobaki(L+) - PE≤ 3.7 kV (at In)
Ure za volteji zilizobaki (L-) - PE≤ 3.7 kV (at In)
Ujumbe wa hitilafu ya ulinzi dhidi ya kuongezeka kwa kasioptical
Halijoto ya mazingira (uendeshaji)-40 °C ... 80 °C
Unyevu unaoruhusiwa (uendeshaji)5 % ... 95 %
Ure za volteji zilizobaki(L+) - (L-)≤ 3.7 kV (at In)
Mkondo wa uendeshaji unaoendelea ICPV< 20 µA
Sehemu ya msalaba ya kondakta imara ya kiwango cha juu.35 mm²
Sehemu nzima ya kondakta dakika.1.5 mm²
Ukadiriaji wa mkondo wa mzunguko mfupi ISCPV1000 A
Mkondo wa kutokwa kwa nominella Katika(L+) - G10 kA
Mkondo wa kutokwa kwa nominella Katika (L-) - G10 kA
Kiwango cha ulinzi wa volteji Juu(L+) - PE≤ 3.7 kV
Kiwango cha ulinzi wa volteji Juu(L-) - PE≤ 3.7 kV
Sehemu ya msalaba ya kondakta inayonyumbulika kwa kiwango cha juu.25 mm²
Sehemu ya msalaba ya kondakta inabadilika kwa kiwango cha chini.1.5 mm²
Ukadiriaji wa ulinzi wa volteji VPR (L-) -G2.5 kV
Ukadiriaji wa kuwaka kulingana na UL 94V-0
Kiwango cha ulinzi wa volteji Juu(L+) - (L-)≤ 3.7 kV
Ukadiriaji wa ulinzi wa volteji VPR (L+) - G2.5 kV
Halijoto ya kawaida (uhifadhi/usafiri)-40 °C ... 80 °C
Mkondo wa kutokwa kwa nominella Katika(L+) - (L-)10 kA
Umbali kati ya sehemu zilizo hai na zilizo chini ya ardhi8 mm
Volti ya juu zaidi ya uendeshaji inayoendelea UCPV1170 V DC
Jumla ya mkondo wa kutokwa kwa umeme ITotal(8/20) µs40 kA
Ukadiriaji wa ulinzi wa volteji VPR (L+) - (L-)2.5 kV
Mahali pa usakinishaji wa kifaa cha kukataInternal
Mkondo wa kutokwa kwa nominella Katika (8/20) µs (L+) - PE15 kA
Mkondo wa kutokwa kwa nominella Katika(8/20) µs (L-) - PE15 kA
Volti ya juu zaidi ya uendeshaji endelevu MCOV (L+) - G1170 V DC
Volti ya juu zaidi ya uendeshaji endelevu MCOV (L-) - G1170 V DC
Kiwango cha juu cha mkondo wa kutokwa kwa kiwango cha juu (8/20) µs (L+) - PE40 kA
Kiwango cha juu cha mkondo wa kutokwa kwa kiwango cha juu (8/20) µs (L-) - PE40 kA
Mkondo wa kutokwa kwa nominella Katika(8/20) µs (L+) - (L-)15 kA
Kiwango cha juu cha mkondo wa kutokwa kwa kiwango cha juu (8/20) µs (L+) - (L-)40 kA
Volti ya juu zaidi ya uendeshaji inayoendelea MCOV (L+) - (L-)1170 V DC

Maelezo ya Bidhaa

Surge protection device for isolated and grounded 2-pole photovoltaic 1000 V DC direct current systems, for rail mounting, 3-pole base element, three plug-in protection elements with temperature contr
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji