| Kipengele | Thamani |
|---|---|
| Bidhaa | Compact Type 4 Safety Beam Sensor |
| PFHD | Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.) |
| MTTFD | More than 100 years (Note:Mean time to dangerous failure (in years)) |
| Uzito | Net weight: 240 g approxGross weight: 450 g approx |
| Maelezo | Controller [High-functional] |
| Nyenzo | Enclosure: ABS |
| Nambari ya Sehemu | ST4-C12EX |
| Jina la bidhaa | Compact Type 4 Safety Beam Sensor ST4 |
| Kebo ya waya | Terminal block connector: 0.2 to 1.5 mm2Power supply connector (A1, A2): 0.2 to 2.5 mm2 |
| Volti ya nguvu | 24 V DC +10-15 % Ripple P-P 10 % or less |
| Muda wa majibu | OFF response: 25 ms or lessON response: 90 ms or less (auto reset) / 140 ms or less (manual reset) |
| Nambari ya Bidhaa | ST4-C12EX |
| Matokeo ya usaidizi | PNP open-collector transistor / NPN open-collector transistor (Set using output polarity selection switch)ST4-C11: one outputST4-C12EX: four outputs[PNP output]Maximum source current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and +V)Residual voltage: 2.5 V or less (at 100 mA source current)[NPN output]Maximum sink current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and 0 V)Residual voltage: 2.0 V or less (at 100 mA sink current)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
| Kuzima taa inayotoa mwangaza | Available muting lamp: 24 V DC, 1 to 10 W(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
| Kituo cha muunganisho | Detachable spring-cage terminal |
| Matumizi ya sasa | 120 mA or less (excluding sensor head ST4-Ax) |
| Viwango vinavyotumika | IEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the controller is used in combination with the sensor head ST4-x. |
| Kichwa cha kitambuzi kinachotumika | ST4-Ax |
| Utii wa maagizo ya kuashiria CE | Machinery Directive, EMC Directive, RoHS Directive |
| Matokeo ya usaidizi: Hali ya uendeshaji | ON when muting function is invalidOFF when muting function is validON when override function is invalidOFF when override function is validON when muting lamp is in normal conditionOFF when muting lamp is in abnormal conditionNegative logic of the control outputs (OSSD1, OSSD2) |
| Matokeo ya udhibiti (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor Dual output x 1 system (Set using output polarity selection switch)[PNP output]Maximum source current: 200 mAApplied voltage: same as the supply voltage (between control output and +V)Residual voltage: 2.5 V or less (at 200 mA source current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. source current)Load wiring resistance: 3 Ohm or less (between control output and load)[NPN output]Maximum sink current: 200 mAApplied voltage: same as the supply voltage (between control output and 0 V)Residual voltage: 2.0 V or less (at 200 mA sink current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. sink current)Load wiring resistance: 3 Ohm or less (between control output and load)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
| Matokeo ya usaidizi: Mzunguko wa Ulinzi | Incorporated |
| Kuzima taa ya kutoa: Mzunguko wa Ulinzi | Incorporated |
| Upinzani wa mazingira: Unyevu wa mazingira | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Upinzani wa mazingira: Upinzani wa mshtuko | 300 m/s2acceleration in X, Y and Z directions three times each |
| Upinzani wa mazingira: Joto la kawaida | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉ |
| Upinzani wa mazingira: Kiwango cha ulinzi | Enclosure: IP40 (IEC)Terminal: IP20 (IEC) |
| Upinzani wa mazingira: Upinzani wa mtetemo | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each< |
| Upinzani wa mazingira: Upinzani wa insulation | 20 MOhm or more with 500 V DC mega between all supply terminals connected together and enclosure |
| Matokeo ya udhibiti (OSSD 1, OSSD 2): Hali ya uendeshaji | ON when all beams of the connected ST4-Axs are receivedOFF when one or more beams of the connected ST4-Axs are interrupted(except during muting / override)OFF during lockout |
| Kichwa cha kitambuzi kinachotumika: Idadi ya miunganisho ya mfululizo | Interference prevention possible when up to a maximum of 6 sets are connected(When the maximum of 3 controllers are connected together, interference prevention is possible for up to 18 sets) |
| Matokeo ya udhibiti (OSSD1, OSSD2): Mzunguko wa ulinzi | Incorporated |
| Upinzani wa mazingira: Ustahimilivu wa voltage | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Speci za kiufundi na data ya utendaji
Mwongozo wa usakinishaji na uendeshaji