| Kipengele | Thamani |
|---|---|
| Bidhaa | Exclusive Control Unit for Safety Light Curtain |
| Uzito | Net weight: 200 g approx. |
| Maelezo | Slim type control unit |
| Ukadiriaji wa fuse | Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down |
| Nambari ya Sehemu | SF-C13 |
| Jina la bidhaa | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| Volti ya nguvu | 24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain) |
| Muda wa majibu | 10 ms or less |
| Matokeo ya usalama | NO contact × 3 (13-14, 23-24, 33-34) |
| Nambari ya Bidhaa | SF-C13 |
| Unyevu wa mazingira | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Kiwango cha uchafuzi wa mazingira | 2 |
| Matokeo ya usaidizi | Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path) |
| Nyenzo ya ufuo | ABS |
| Halijoto ya mazingira | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉ |
| Kituo cha muunganisho | Spring-cage terminal |
| Matumizi ya sasa | 100 mA or less (without light curtain) |
| Kategoria ya volteji nyingi | II |
| Upinzani wa mtetemo | Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm0.014 inamplitudein X, Y, and Z directions for twenty times each |
| Kipengele cha ukingo wa kufuatia | Incorporated |
| Viashiria: Kosa (KOSA) | Yellow LED (blinks when fault occurs) |
| Viwango vinavyotumika: Japani | JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), |
| Kipengele cha uteuzi wa polari | Incorporated (Cable connection allows selection of plus/minus ground)Minus ground: Correspond to PNP output safety light curtainPlus ground: Correspond to NPN output safety light curtain(Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.) |
| Viashiria: Ugavi wa umeme (UI) | Green LED (lights up when the power is ON) |
| Viashiria: Matokeo ya usalama [OUT] | Green LED (lights up when safety output is closed)(Note:The operation indicator is marked as "Enabling" on the unit forSF-C12.) |
| Utii wa maagizo ya kuashiria CE | Machinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive |
| Kitendaji cha kifuatiliaji cha nje cha relay | Incorporated |
| Viwango vinavyotumika: Ulaya (EU) | EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe)(Note:SF-C11andSF-C13comply with UL 1998 (Class 2).) |
| Pato la usalama: Upinzani wa mawasiliano | 100 mOhm or less (initial value) |
| Mapazia ya taa za usalama yanayoweza kuunganishwa | Safety light curtain manufactured by Panasonic Industrial Devices SUNX |
| Viashiria: Kufunga kwa ndani (INTER_LOCK) | Yellow LED (lights up when enabling contacts are opened) |
| Pato la usalama: Muda wa matumizi ya umeme | 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| Pato la usalama: Maisha ya mitambo | 10,000,000 times or more (open/close frequency of 180 times/min)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| Viwango vinavyotumika: Amerika Kaskazini | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note:SF-C11andSF-C13comply with UL 1998 (Class 2).) |
| Matokeo ya usalama: Aina ya programu | AC-15, DC-13 (IEC 60947-5-1) |
| Pato saidizi la semiconductor (AUX) | PNP open-collector transistor・Max. source current: 60 mA・Applied voltage: same as supply voltage(between the semiconductorauxiliary output and +V)・Residual voltage: 2.3 V or less(at source current 60 mA)Leakage current: 2 mA or less |
| Kuchelewa kuchukuliwa (Kuweka upya kiotomatiki / Kuweka upya mwenyewe) | 80 ms or less / 90 ms or less |
| Matokeo ya usalama: Nyenzo za mawasiliano / anwani | AgSnO, self cleaning, positively driven |
| Viwango vinavyotumika: Kiwango cha kimataifa | IEC 61496-1 (Type 4) |
| Pato la usalama: Fuse ya ulinzi wa mawasiliano ilikadiriwa | 4 A (slow blow) |
| Upinzani wa mazingira: Kiwango cha ulinzi | Enclosure: IP40Terminal: IP20 |
| Pato la msaidizi: Fuse ya ulinzi wa mawasiliano ilikadiriwa | 2 A (slow blow) |
| Pato la msaidizi: Voltage ya uendeshaji iliyokadiriwa / mkondo | 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) |
| Pato saidizi la semiconductor(AUX): Uendeshaji wa pato | On when the safety light curtain is interrupted |
| Pato la usalama: Volti ya uendeshaji iliyokadiriwa (Ue) /Mkondo wa uendeshaji uliokadiriwa (le) | 4 A / 30 V DC, 4 A / 230 V AC, resistive load (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC)(Note:If severalSF-C11orSF-C13units are being used in a line together, leavea space of 5 mm0.197 inor more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below.) |
Speci za kiufundi na data ya utendaji
Mwongozo wa usakinishaji na uendeshaji