Muda wa huduma: Jumatatu hadi Ijumaa 9:00-18:00
ULSH102C5 - ULSH102C5 LS-H102-C5 PANASONIC Sensor head, thru-beam, side sensing type, range 1m, cable 5m
Kipatikana Bidhaa Maarufu

ULSH102C5

ULSH102C5 LS-H102-C5 PANASONIC Sensor head, thru-beam, side sensing type, range 1m, cable 5m

$0.00USD
4324 kwenye hisa
Vipimo Muhimu
Bidhaa:Amplifier-separated Type Digital Laser Sensor
Kebo:0.09 mm22-core shielded cable, 2 m 6.562 ft long(Note:Cable cannot be extended.)
Maelezo:Sensor heads(Thru-beam type)
Nyenzo:Enclosure: PBTCover: Acrylic
Taarifa za Msambazaji
PANASONIC
PANASONIC
Bidhaa: 4316
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
BidhaaAmplifier-separated Type Digital Laser Sensor
Kebo0.09 mm22-core shielded cable, 2 m 6.562 ft long(Note:Cable cannot be extended.)
MaelezoSensor heads(Thru-beam type)
NyenzoEnclosure: PBTCover: Acrylic
Kifaa cha ziadaMS-EXL2-2 (Mounting plate): 2 pcs.
Ukubwa wa doaApprox. dia. 5 mm dia. 0.197 in or less (at a distance from the emitter of 1 m 3.281 ft)
UlinziIP67 (IEC)
Nambari ya SehemuLS-H102-C5
Jina la bidhaaAmplifier-separated Type Digital Laser Sensor LS-500
Nambari ya BidhaaLS-H102-C5
Kitu cha kuhisiOpaque, translucent, or transparent object(Note:Make sure to confirm detection with an actual sensor before use.)
Unyevu wa mazingira35 to 85 % RH, Storage: 35 to 85 % RH
Upinzani wa mshtuko98 m / s2acceleration (10 G approx.) in X, Y and Z directions three times each
Kiwango cha kuhisi: HYPR1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Kiwango cha kuhisi: U-LG1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Mwangaza wa mazingiraIncandescent light: 3,000 ℓx or less at the light-receiving face
Halijoto ya mazingira-10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit
Kiashiria cha uendeshajiOrange LED (lights up when the amplifier output is ON)
Upinzani wa mtetemo10 to 500 Hz frequency, 1.5 mm double amplitude or maximum acceleration 98 m/s2in X, Y, and Z direction for 2 hours each.
Vikuzaji vinavyotumikaLS-501(P), LS-501(P)-C2(Note:When using the thru-beam typeLS-H101□orLS-H102□, do not set the receiving light sensitivity (gctL) of the applicableLS-500series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.)
Kipengele kinachotoa: AinaRed semiconductor laser diode
Upinzani wa insulation20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Utiifu wa kanuniEMC Directive, RoHS Directive
Kiwango cha kuhisi: Hali ya STD1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Kiwango cha kuhisi: Hali ya FAST1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Kiwango cha kuhisi: Hali ya H-SP1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Kiwango cha kuhisi: Hali ya U-LG1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Ustahimilivu wa volteji1,000 V AC for one min. between all supply terminals connected together and enclosure
Kipengele kinachotoa: Darasa la laserClass 1 [IEC / EN / JIS / GB / KS / FDA](Note:This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
Kipengele kinachotoa: Upeo wa juu zaidi wa matokeo2mW
Kipengele kinachotoa moshi: Urefu wa kilele cha utoaji wa mawimbi660 nm 0.026 mil

Maelezo ya Bidhaa

LS500. Sensor head, barrier, side detection, range 1m, cable 5m
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji

Top