Vipimo Muhimu
GTIN:4055626135540
Ufunguo wa kuagiza:2906799
(Jumla):D1 - 500 A
(Michoro):
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
GTIN4055626135540
Ufunguo wa kuagiza2906799
(Jumla)D1 - 500 A
(Michoro)
Ukurasa wa katalogiPage 130 (C-4-2019)
Kitengo cha kufungasha1 pc
Kina (Michoro)69.5 mm (incl. DIN rail 7.5 mm)
UNSPSC 11 (ETIM)39121610
Upana (Michoro)6.2 mm +0.1 mm
Nchi ya asiliDE (Germany)
ETIM 2.0 (eCl@ss)EC000943
ETIM 3.0 (eCl@ss)EC000943
ETIM 4.0 (eCl@ss)EC000943
ETIM 5.0 (eCl@ss)EC000943
ETIM 6.0 (eCl@ss)EC000943
ETIM 7.0 (eCl@ss)EC000943
Urefu (Michoro)105.8 mm
(Data ya muunganisho)EN 61643-21 2001 + A1:2009 + A2:2013
Mchoro (Michoro)
UNSPSC 13.2 (ETIM)39121620
UNSPSC 18.0 (ETIM)39121620
UNSPSC 19.0 (ETIM)39121620
UNSPSC 20.0 (ETIM)39121620
UNSPSC 21.0 (ETIM)39121620
UNSPSC 6.01 (ETIM)30212010
UNSPSC 12.01 (ETIM)39121610
Nambari ya ushuru maalum85363010
Picha (Michoro)
UNSPSC 7.0901 (ETIM)39121610
Urefu (Vipimo)≤ 4000 m (amsl (above mean sea level))
Mkondo uliokadiriwa (Jumla)600 mA (40 °C)
Aina (Hali za mazingira)DIN rail module, one-piece
Rangi (Hali ya mazingira)traffic grey A RAL 7042
(Viwango na Kanuni)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Volti ya kawaida UN (Jumla)24 V DC
eCl@ss 4.0 (Uainishaji)27140201
eCl@ss 4.1 (Uainishaji)27130801
eCl@ss 5.0 (Uainishaji)27130801
eCl@ss 5.1 (Uainishaji)27130801
eCl@ss 6.0 (Uainishaji)27130800
eCl@ss 7.0 (Uainishaji)27130807
eCl@ss 8.0 (Uainishaji)27130807
eCl@ss 9.0 (Uainishaji)27130807
Upinzani kwa kila njia (Jumla)1.65 Ω ±20 %
IPE ya mkondo uliobaki (Jumla)≤ 10 µA
Uwezo (mstari-ardhi) (Jumla)typ. 2.2 nF
Kiwango cha ulinzi (Vipimo)IP20
Uainishaji wa mtihani wa IEC (Jumla)C1
Aina ya kupachika (Hali ya mazingira)DIN rail: TH 35 - 7.5 mm
Fuse ya chelezo inayohitajika kwa kiwango cha juu zaidi (Jumla)630 mA (FF)
Uzito kwa Kipande (bila kujumuisha upakiaji)40.000 g
Nyenzo za makazi (Hali ya mazingira)PBT
Upunguzaji wa pembejeo aE, asym. (Jumla)typ. 0.3 dB (≤ 270 kHz/150 Ω)
RoHS ya China (Viwango na Kanuni)Environmentally Friendly Use Period = 50
REACh SVHC (Viwango na Kanuni)Lead 7439-92-1
Muda wa majibu tA(line-earth) (Jumla)≤ 1 ns
Volti ya juu inayoendelea UC (Jumla)30 V DC
Muda wa kuweka upya mapigo (mstari-ardhi) (Jumla)≤ 300 ms
Mwelekeo wa kitendo (Hali za mazingira)Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Uzi wa skrubu (Data ya ziada ya kiufundi)M3
Uimara wa msukumo (mstari-ardhi) (Jumla)C1 - 1 kV / 500 A
Viwango/vipimo (Data ya muunganisho)IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
Halijoto ya mazingira (uendeshaji) (Vipimo)-40 °C ... 85 °C
Urefu wa kukatwa (Data ya ziada ya kiufundi)8 mm
Mbinu ya muunganisho (Data ya ziada ya kiufundi)Screw connection
Inafanya kazi kwa ufanisi sasa ICat UC (Jumla)≤ 5 µA
Unyevu unaoruhusiwa (uendeshaji) (Vipimo)5 % ... 95 %
Kukaza torque (Data ya ziada ya kiufundi)0.5 Nm ... 0.6 Nm
Kiwango cha ulinzi wa volteji Juu (mstari-ardhi) (Jumla)≤ 140 V (C1 - 1 kV/500 A)
Jumla ya mkondo wa kutokwa Jumla (8/20) µs (Jumla)10 kA
Halijoto ya kawaida (uhifadhi/usafiri) (Vipimo)-40 °C ... 85 °C
Sehemu ya msalaba ya kondakta AWG (Data ya ziada ya kiufundi)24 ... 12
Kiwango cha ulinzi wa volteji Kilicho juu (mstari-ardhi) (Jumla)≤ 55 V (C1 - 1 kV/500 A)
Sehemu ngumu ya kondakta (Data ya ziada ya kiufundi)0.2 mm² ... 4 mm²
Ukadiriaji wa kuwaka kulingana na UL 94 (Hali ya mazingira)V-0
Sehemu ya msalaba ya kondakta inayonyumbulika (Data ya ziada ya kiufundi)0.2 mm² ... 2.5 mm²
Mkondo wa kutokwa kwa nominella Katika (8/20) µs (line-earth) (Jumla)5 kA
Mkondo wa kutokwa kwa mapigo Iimp(10/350) µs (line-earth) (Jumla)0.5 kA
Frequency ya kukatwa fg (3 dB), asym. (PE) katika mfumo wa 150 Ohm (Jumla)typ. 960 kHz
Jumla ya jumla ya mkondo wa kutokwa Jumla ya juu zaidi (8/20) µs (Mzunguko wa kinga)20 kA (1x)

Maelezo ya Bidhaa

Surge protection for two signal conductors with common reference potential, e.g. digital INPUT/OUTPUT.
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Maelezo ya Kiufundi

Diagram

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji

Top