| Kipengele | Thamani |
|---|---|
| C2 | |
| Dokezo | 2000 + corrigendum 2001 + A1:2008, modified + A2:2012 |
| Aina | DIN rail module, one-piece |
| Kina | 69.5 mm (incl. DIN rail 7.5 mm) |
| Upana | 6.2 mm +0.1 mm |
| Urefu | ≤ 4000 m (amsl) |
| Aina ya bidhaa | Surge protection for MCR technology |
| Aina ya kupachika | DIN rail: TH 35 - 7.5 mm |
| Imekadiriwa mkondo | 450 mA (80 °C) |
| Familia ya bidhaa | TERMITRAB complete |
| Fungua paneli ya pembeni | No |
| Marekebisho ya makala | 03 |
| Nyenzo za makazi | PBT |
| Kiwango cha uchafuzi wa mazingira | 2 |
| Mbinu ya muunganisho | Push-in connection |
| Volti ya kawaida ya Umoja wa Mataifa | 24 V DC |
| Mchoro wa vipimo | |
| Mwelekeo wa kitendo | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
| Nyenzo za kuhami joto | PBT |
| Upinzani kwa kila njia | ≤ 100 mΩ |
| Kiwango cha ulinzi | IP20 |
| Kategoria ya volteji nyingi | III |
| IPE ya mkondo uliobaki | ≤ 1 µA |
| Uwezo (Kiini-Dunia) | typ. 2.2 nF |
| Uainishaji wa mtihani wa IEC | C1 |
| Viwango/vipimo | IEC 61643-21 |
| Upunguzaji wa pembejeo aE, ulinganifu. | typ. 0.3 dB (≤ 300 kHz / 150 Ω) |
| Fuse ya kuhifadhi nakala rudufu inayohitajika kwa kiwango cha juu zaidi | 500 mA (FF) |
| Sehemu ya msalaba ya kondakta AWG | 24 ... 12 |
| Muda wa majibu tA (mstari-mstari) | ≤ 1 ns |
| Muda wa majibu tA(line-earth) | ≤ 100 ns |
| Sehemu ngumu ya kondakta | 0.2 mm² ... 4 mm² |
| Kiwango cha juu cha voltage inayoendelea UC | 30 V DC |
| Muda wa kuweka upya mapigo (mstari-ardhi) | ≤ 1 s |
| Uimara wa msukumo (mstari-mstari) | C1 - 1 kV / 500 A |
| Ujumbe wa hitilafu ya ulinzi dhidi ya kuongezeka kwa kasi | none |
| Halijoto ya mazingira (uendeshaji) | -40 °C ... 85 °C |
| Uimara wa msukumo (mstari-ardhi) | C1 - 1 kV / 500 A |
| Sehemu ya msalaba ya kondakta inayonyumbulika | 0.2 mm² ... 2.5 mm² |
| Unyevu unaoruhusiwa (uendeshaji) | 5 % ... 95 % |
| Inafanya kazi kwa ufanisi ICat UC ya sasa | ≤ 5 µA |
| Ukadiriaji wa kuwaka kulingana na UL 94 | V-0 |
| Kiwango cha ulinzi wa voltage Juu (mstari-mstari) | ≤ 60 V (C1 - 1 kV / 500 A) |
| Halijoto ya kawaida (uhifadhi/usafiri) | -40 °C ... 85 °C |
| Kiwango cha ulinzi wa volteji Juu (mstari-ardhi) | ≤ 650 V (C1 - 1 kV / 500 A) |
| Jumla ya mkondo wa kutokwa Jumla (8/20) µs | 10 kA |
| Kiwango cha ulinzi wa volteji Kilicho juu (mstari-ardhi) | ≤ 1.1 kV (C2 - 10 kV / 5 kA) |
| Jumla ya jumla ya mkondo wa kutokwa Jumla ya juu zaidi (8/20) µs | 20 kA (1x) |
| Mkondo wa kutokwa kwa nominella Katika (8/20) µs (mstari-mstari) | 0.5 kA |
| Frequency ya kukatwa fg (3 dB), ulinganifu katika mfumo wa 150 Ω | typ. 965 kHz |
| Mkondo wa kutokwa kwa nominella Katika (8/20) µs (ms) | 5 kA |
| Mkondo wa kutokwa kwa mapigo Iimp(10/350) µs (line-earth) | 0.5 kA |