| Kipengele | Thamani |
|---|---|
| GTIN | 4055626810683 |
| Ufunguo wa kuagiza | 1081867 |
| (Michoro) | |
| Kitengo cha kufungasha | 1 |
| ETIM 4.0 (eCl@ss) | EC000816 |
| ETIM 5.0 (eCl@ss) | EC000268 |
| ETIM 6.0 (eCl@ss) | EC000268 |
| ETIM 7.0 (eCl@ss) | EC000268 |
| Nambari ya ushuru maalum | 85363030 |
| System voltage (Drawings) | 1000 V DC (Umax) |
| Number of outputs (Drawings) | 1 (per MPP tracker) |
| eCl@ss 5.1 (Uainishaji) | 27371890 |
| eCl@ss 7.0 (Uainishaji) | 27142422 |
| eCl@ss 8.0 (Uainishaji) | 27142422 |
| eCl@ss 9.0 (Uainishaji) | 27142422 |
| Darasa la ulinzi (Kiingilio cha kebo) | II |
| eCl@ss 10.0.1 (Uainishaji) | 27142422 |
| Kifuniko/mlango wa nyenzo (Kiingilio cha kebo) | Polycarbonate (transparent) |
| Kiwango cha ulinzi (Kiingilio cha kebo) | IP65 |
| Number of string inputs (Drawings) | 2 (per MPP tracker) |
| Current per string (max.) (Drawings) | 20 A (Imax) |
| Kiwango cha Ulinzi Juu (Kigezo cha Mfumo) | ≤ 3.5 kV |
| Towe la eneo la kuziba (Vifaa vya usalama) | 3 mm ... 6.5 mm |
| Aina ya kebo ya kuingilia (Vifaa vya usalama) | Cable gland |
| Kutuliza eneo la kuziba (Vifaa vya usalama) | 6 mm ... 12 mm (2x) |
| Kifaa cha kinga ya kuongezeka (Kigezo cha mfumo) | T1 / T2 |
| Number of supported MPP trackers (Drawings) | 4 |
| Halijoto ya mazingira (uendeshaji) (Vipimo) | -20 °C ... 55 °C |
| Ingizo la kamba ya eneo la kuziba (Vifaa vya usalama) | 3 mm ... 6.5 mm |
| Towe la sehemu nzima ya kebo (Vifaa vya usalama) | 2.5 mm² ... 6 mm² |
| Kutuliza sehemu ya msalaba wa kebo (Vifaa vya usalama) | 16 mm² (2 x) |
| Ingizo la kamba ya sehemu nzima ya kebo (Vifaa vya usalama) | 2.5 mm² ... 6 mm² |
| Vipimo vya nje: upana, urefu, kina (Data ya jumla) | 361 mm x 254 mm x 111 mm (Housing dimensions) |
| Connection diagramSchematic application drawing (Drawings) | |
| Total discharge current Itotal(8/20) µs (System parameter) | 40 kA |
| Total discharge current Itotal(10/350) µs (System parameter) | 5 kA |
| Schematic diagramConnection of the protective grounding conductor (Drawings) | |
| Circuit diagramConnection of the remote indication contact on the surge protection (Drawings) |