| Kipengele | Thamani |
|---|---|
| C2 | |
| Dokezo | Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector. |
| Aina | DIN rail module, two-section, divisible |
| Kina | 77.5 mm (incl. DIN rail 7.5 mm) |
| Upana | 17.7 mm |
| Urefu | ≤ 4000 m (amsl) |
| Aina ya bidhaa | Surge protection for MCR technology |
| Uzi wa skrubu | M3 |
| Aina ya kupachika | DIN rail: 35 mm |
| Imekadiriwa mkondo | 1000 mA (40 °C) |
| Familia ya bidhaa | PLUGTRAB IQ |
| Mlalo wa sauti | 1 Div. |
| Nyenzo za makazi | PA 6.6 |
| Kiwango cha uchafuzi wa mazingira | 2 |
| Mbinu ya muunganisho | Screw connection |
| Kukaza torque | 0.5 Nm |
| Volti ya kawaida ya Umoja wa Mataifa | 5 V DC |
| Mchoro wa vipimo | |
| Mwelekeo wa kitendo | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
| Upinzani kwa kila njia | 1.2 Ω ±5 % |
| Kiwango cha ulinzi | IP20 |
| Kategoria ya volteji nyingi | III |
| IPE ya mkondo uliobaki | ≤ 2 µA (per signal circuit) |
| Uwezo (Kiini-Dunia) | typ. 7.5 nF |
| Jozi za waya kwa kila moduli | 1 |
| Uainishaji wa mtihani wa IEC | C1 |
| Viwango/vipimo | IEC 61643-21 |
| Upunguzaji wa pembejeo aE, ulinganifu. | typ. 0.3 dB (≤ 40 kHz/150 Ω) |
| Fuse ya kuhifadhi nakala rudufu inayohitajika kwa kiwango cha juu zaidi | 1 A (FF) |
| Sehemu ya msalaba ya kondakta AWG | 24 ... 12 |
| Muda wa majibu tA (mstari-mstari) | ≤ 1 ns |
| Muda wa kuweka upya mapigo (mstari-mstari) | ≤ 10 ms |
| Muda wa majibu tA(line-earth) | ≤ 100 ns |
| Sehemu ngumu ya kondakta | 0.2 mm² ... 4 mm² |
| Kiwango cha juu cha voltage inayoendelea UC | 6 V DC |
| Muda wa kuweka upya mapigo (mstari-ardhi) | ≤ 10 ms |
| Uimara wa msukumo (mstari-mstari) | C1 - 1 kV / 500 A |
| Ujumbe wa hitilafu ya ulinzi dhidi ya kuongezeka kwa kasi | Optical, multi-stage |
| Halijoto ya mazingira (uendeshaji) | -40 °C ... 70 °C |
| Uimara wa msukumo (mstari-ardhi) | C1 - 1 kV / 500 A |
| Sehemu ya msalaba ya kondakta inayonyumbulika | 0.2 mm² ... 2.5 mm² |
| Inafanya kazi kwa ufanisi ICat UC ya sasa | ≤ 2 mA (in the signal circuit) |
| Ukadiriaji wa kuwaka kulingana na UL 94 | V-0 |
| Kiwango cha ulinzi wa voltage Juu (mstari-mstari) | ≤ 85 V (C1 - 1 kV / 500 A) |
| Halijoto ya kawaida (uhifadhi/usafiri) | -40 °C ... 85 °C |
| Kiwango cha ulinzi wa volteji Juu (mstari-ardhi) | ≤ 600 V (C1 - 1 kV / 500 A) |
| Jumla ya mkondo wa kutokwa Jumla (8/20) µs | 20 kA |
| Kiwango cha ulinzi wa volteji Kinachobadilika (mstari-wa-safu) | ≤ 26 V (C1 - 1 kV / 500 A) |
| Mkondo wa kutokwa kwa nominella Katika (8/20) µs (mstari-mstari) | 10 kA |
| Frequency ya kukatwa fg (3 dB), ulinganifu katika mfumo wa 150 Ω | typ. 300 kHz |
| Mkondo wa kutokwa kwa nominella Katika (8/20) µs (ms) | 10 kA |
| Mkondo wa kutokwa kwa mapigo Iimp(10/350) µs (line-earth) | 2.5 kA |
Speci za kiufundi na data ya utendaji
Mwongozo wa usakinishaji na uendeshaji