| Kipengele | Thamani |
|---|---|
| High demand | |
| Kina | 112 mm |
| Mshtuko | 15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.) |
| Upana | 22.5 mm |
| Urefu | 114.5 mm |
| Kategoria | 1 |
| inayoweza kuziba | yes |
| Aina ya reli | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Maombi | Safe switch off |
| Cheti | CE-compliant |
| Fuse ya kutoa | 10 A gL/gG (N/O contact) |
| Aina ya bidhaa | Coupling relay |
| Muda wa kuanzisha upya | < 1 s (Boot time) |
| Aina ya kupachika | DIN rail mounting |
| Muda wa kupona | < 500 ms |
| Kategoria ya kuacha | 0 |
| Mkondo wa ndani | typ. 350 mA DC (Δt s) |
| Familia ya bidhaa | PSRclassic |
| Rangi (Nyumba) | yellow (RAL 1018) |
| Marekebisho ya makala | 06 |
| Nyenzo ya mawasiliano | AgSnO2 |
| Nyenzo za makazi | Polyamide |
| Urefu wa juu zaidi | max. 2000 m (Above sea level) |
| Urefu wa kukatwa | 8 mm |
| Mbinu ya muunganisho | Push-in connection |
| Nafasi ya kupachika | vertical or horizontal |
| Jumla ya mkondo wa mraba | 48 A2 |
| Kukaza torque | 0.6 Nm |
| Mzunguko wa kinga | Surge protection; Suppressor diode |
| Uwezo wa kubadili | min. 50 mW |
| Kiwango cha volteji ya kuingiza | 20.4 V AC/DC ... 26.4 V AC/DC |
| Dokezo kwenye programu | Only for industrial use |
| Kiwango cha ulinzi | IP20 |
| Muda wa kawaida wa kutolewa | typ. 15 ms (when controlled via A1) |
| Viwango/kanuni | DIN EN 50178 |
| Mtetemo (uendeshaji) | 10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.) |
| Aina ya ubadilishaji wa mguso | 3 enabling current paths |
| Kiwango cha juu cha mkondo wa kukimbilia | 8 A |
| Hali ya uendeshaji ya nominella | 100% operating factor |
| Kiwango cha Utendaji (PL) | c |
| Mkondo wa kukimbilia, kiwango cha chini kabisa | 10 mA |
| Maisha ya huduma ya mitambo | 10x 106cycles |
| Matumizi ya umeme nchini Marekani | typ. 1.08 W |
| Volti ya insulation iliyokadiriwa | 250 V |
| Volti ya juu zaidi ya kubadili | 230 V AC/DC (Observe the load curve) |
| Volti ya chini kabisa ya kubadili | 5 V AC/DC |
| Onyesho la volteji ya uendeshaji | 1 x green LED |
| Andika muda wa kuanza nasi | typ. 15 ms (when controlled via A1) |
| AWG ya sehemu mtambuka ya kondakta | 24 ... 16 |
| Kupunguza mkondo unaoendelea | 6 A (N/O contact) |
| Masafa ya juu zaidi ya kubadili | 0.5 Hz |
| Kiwango cha Uadilifu wa Usalama (SIL) | 1 |
| Sehemu ngumu ya kondakta | 0.2 mm² ... 1.5 mm² |
| Volti/insulation ya kuongezeka iliyokadiriwa | 4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.) |
| Halijoto ya mazingira (uendeshaji) | -20 °C ... 55 °C |
| Udhibiti wa sasa wa usambazaji wa udhibiti uliokadiriwa IS | typ. 45 mA |
| Sehemu ya msalaba ya kondakta inayonyumbulika | 0.2 mm² ... 1.5 mm² |
| Kiwango cha juu cha ukadiriaji wa kukatiza (mzigo wa ohmic). | For additional values, see load curve |
| Halijoto ya kawaida (uhifadhi/usafiri) | -40 °C ... 70 °C |
| Volti ya usambazaji wa mzunguko wa udhibiti iliyokadiriwa Marekani | 20.4 V AC/DC ... 26.4 V AC/DC |
| Kiwango cha chini cha ulinzi wa eneo la taasisi | IP54 |
| Ukadiriaji wa juu zaidi wa kukatiza (mzigo wa kushawishi) | 48 W (N/O contact, 24 V DC, τ = 40 ms) |
| Unyevu wa juu unaoruhusiwa (uhifadhi/usafiri) | 75 % (on average, 85% infrequently, non-condensing) |
| Kiwango cha juu cha unyevu kinachoruhusiwa (uendeshaji) | 75 % (on average, 85% infrequently, non-condensing) |
| Usambazaji wa nguvu wa kiwango cha juu kwa hali ya kawaida | 6.11 W (at UB= 26.4 V DC, US= 24 V, IS= 45 mA, n = 1, IL² = 48 A², Rcontact= 0.1 ) |
| Uwezo wa kubadili kulingana na IEC 60947-5-1 | 5 A (24 V (DC13)) |
| Sehemu ya msalaba ya kondakta, inayonyumbulika, yenye kipete, na kifuniko cha plastiki | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Sehemu ya msalaba ya kondakta inayonyumbulika, yenye kipete bila kifuniko cha plastiki | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
Speci za kiufundi na data ya utendaji