| Kipengele | Thamani |
|---|---|
| max. 250 V AC | |
| Kina | 114.5 mm |
| Mshtuko | 15g |
| Upana | 22.5 mm |
| Urefu | 112.2 mm |
| Kategoria | 3 |
| inayoweza kuziba | yes |
| Aina ya reli | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Maombi | Extension module |
| Fuse ya kutoa | 10 A gL/gG |
| Aina ya bidhaa | Safety relays |
| Uzi wa skrubu | M3 |
| Aina ya kupachika | DIN rail mounting |
| Seti inajumuisha | 1397657 PSR-ME30-4NO-1NC-24DC-SC-SET35 |
| Kategoria ya kuacha | 0 |
| Utambulisho | CE-compliant |
| Mkondo wa ndani | typ. 130 mA (Δt = 800 ms) |
| Familia ya bidhaa | PSRclassic |
| Nyenzo ya mawasiliano | AgSnO2 |
| Nyenzo za makazi | Polyamide |
| Urefu wa juu zaidi | ≤ 2000 m (Above sea level) |
| Idadi ya pembejeo | 1 |
| Urefu wa kukatwa | 7 mm |
| Mbinu ya muunganisho | Screw connection |
| Nafasi ya kupachika | vertical or horizontal |
| Idadi ya matokeo | 4 |
| Jumla ya mkondo wa mraba | 72 A2(observe derating) |
| Volti ya kubadili | min. 10 V AC/DC |
| Kukaza torque | 0.5 Nm ... 0.6 Nm |
| Maelezo ya matokeo | 2 N/O contacts each in series, safety-related, floating |
| Mzunguko wa kinga | Suppressor diode |
| Uwezo wa kubadili | min. 100 mW |
| Matumizi ya sasa | typ. 67 mA |
| Masafa ya kubadili | max. 0.5 Hz |
| Kiwango cha ulinzi | IP20 |
| Muda wa kawaida wa kutolewa | 20 ms (when requested via K1/K2) |
| Maagizo ya kusanyiko | See derating curve |
| Viwango/kanuni | DIN EN 60947-1 |
| Mtetemo (uendeshaji) | 10 Hz ... 150 Hz, 2g |
| Aina ya ubadilishaji wa mguso | 4 enabling current paths |
| Hali ya uendeshaji ya nominella | 100% operating factor |
| Kiwango cha Utendaji (PL) | d |
| Maisha ya huduma ya mitambo | approx. 107cycles |
| Maelezo ya ingizo | safety-related |
| Volti ya insulation iliyokadiriwa | 250 V |
| Onyesho la volteji ya uendeshaji | 1 x green LED |
| Andika muda wa kuanza nasi | 20 ms (when controlled via K1/K2) |
| AWG ya sehemu mtambuka ya kondakta | 24 ... 12 |
| Kupunguza mkondo unaoendelea | 6 A (Observe derating and load limit curve) |
| Kiwango cha Uadilifu wa Usalama (SIL) | 2 |
| Sehemu ngumu ya kondakta | 0.2 mm² ... 2.5 mm² |
| Ishara ya kiwango cha voltage ya kuingiza "1" | 20.4 V ... 26.4 V |
| Volti/insulation ya kuongezeka iliyokadiriwa | See section “Insulation coordination” |
| Halijoto ya mazingira (uendeshaji) | -20 °C ... 55 °C (observe derating) |
| Sehemu ya msalaba ya kondakta inayonyumbulika | 0.2 mm² ... 2.5 mm² |
| Halijoto ya kawaida (uhifadhi/usafiri) | -40 °C ... 70 °C |
| Kiwango cha chini cha ulinzi wa eneo la taasisi | IP54 |
| Unyevu wa juu unaoruhusiwa (uhifadhi/usafiri) | 75 % (on average, 85% infrequently, non-condensing) |
| Upinzani wa jumla wa kondakta unaoruhusiwa wa kiwango cha juu zaidi | 50 Ω |
| Kiwango cha juu cha unyevu kinachoruhusiwa (uendeshaji) | 75 % (on average, 85% infrequently, non-condensing) |
| Usambazaji wa nguvu wa kiwango cha juu kwa hali ya kawaida | 16.4 W (UK1/K2= 26.4 V, IL² = 72 A², PTotal max= 2 W + 14.4 W) |
| Uwezo wa kubadili kulingana na IEC 60947-5-1 | 5 A (AC15) |
Speci za kiufundi na data ya utendaji