| Kipengele | Thamani |
|---|---|
| GTIN | 4046356681865 |
| Ufunguo wa kuagiza | 2902830 |
| (Data ya EMC) | Class I, Zone 2, Group IIC |
| Ukurasa wa katalogi | Page 102 (C-7-2015) |
| Kina (Dokezo) | 102.5 mm |
| Kitengo cha kufungasha | 1 pc |
| Upana (Dokezo) | 6.2 mm |
| Urefu (Dokezo) | 93.1 mm |
| ATEX (data ya EMC) | II 3 G Ex nA IIC T4 Gc X |
| Nchi ya asili | DE (Germany) |
| (Data ya muunganisho) | Class I, Zone 2, Group IIC |
| Maoni (data ya EMC) | Criterion B |
| Ripple (Data ya kuingiza) | < 20 mVPP(at 500 Ω) |
| Nambari ya ushuru maalum | 85437090 |
| (Hali ya mazingira) | 0.4 mA ... 2 mA |
| Uteuzi (Jumla) | Conducted interferences |
| ATEX (data ya muunganisho) | II 3 G Ex nA IIC T4 Gc X |
| Ulinganifu (data ya EMC) | CE-compliant |
| Uteuzi (data ya EMC) | Conducted interferences |
| Rangi (Data ya muunganisho) | green |
| Utoaji wa kelele (data ya EMC) | EN 61000-6-4 |
| UL, Marekani/Kanada (data ya EMC) | UL 508 Listed |
| (Viwango na Kanuni) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Ulinganifu (Data ya muunganisho) | CE-compliant |
| Idadi ya matokeo (Data ya kuingiza) | 1 |
| Kutengwa kwa umeme (data ya EMC) | Basic insulation according to EN 61010 |
| Matumizi ya nguvu (Data ya matokeo) | 28 mW (without signal) |
| Viwango/kanuni (Jumla) | EN 61000-4-6 |
| Urefu wa kukatwa (Ugavi wa umeme) | 8 mm |
| Muda wa mpangilio (Data ya muunganisho) | ± 2 % |
| Sufuri ya mpangilio (Data ya muunganisho) | ± 2 % |
| Njia ya muunganisho (Usambazaji wa umeme) | Spring-cage connection |
| Mkondo wa juu zaidi wa kutoa (Data ya kuingiza) | 35 mA (output limit) |
| Utoaji wa kelele (Data ya muunganisho) | EN 61000-6-4 |
| Kinga ya kelele (Data ya muunganisho) | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| Viwango/kanuni (data ya EMC) | EN 61000-4-6 |
| UL, Marekani/Kanada (Data ya muunganisho) | UL 508 Listed |
| Idadi ya njia (Data ya muunganisho) | 1 |
| Ishara ya sasa ya kutoa (Data ya kuingiza) | 4 mA ... 20 mA |
| Nyenzo za makazi (Data ya muunganisho) | PBT |
| Kiwango cha volteji ya usambazaji (Data ya matokeo) | no separate supply voltage necessary |
| Nafasi ya kupachika (Data ya muunganisho) | any |
| Uzito kwa Kipande (bila kujumuisha upakiaji) | 74.400 g |
| Kiwango cha uchafuzi (Data ya muunganisho) | 2 |
| Idadi ya ingizo (Hali ya mazingira) | 1 |
| RoHS ya China (Viwango na Kanuni) | Environmentally Friendly Use Period = 50 |
| Inaweza kusanidiwa/kupangwa (Data ya kuingiza) | Yes, preconfigured |
| Kutengwa kwa umeme (Data ya muunganisho) | Basic insulation according to EN 61010 |
| Kategoria ya volteji kupita kiasi (Data ya muunganisho) | II |
| REACh SVHC (Viwango na Kanuni) | Lead 7439-92-1 |
| Mkondo wa pembejeo wa juu zaidi (Hali za mazingira) | < 50 mA (Dielectric strength up to 30 V) |
| Volti ya juu zaidi ya kuingiza (Hali za mazingira) | < 40 V |
| Utangamano wa sumaku-umeme (data ya EMC) | Conformance with EMC directive |
| Masafa ya kikomo (3 dB) (Data ya muunganisho) | approx. 30 Hz |
| Jibu la hatua (10-90%) (Data ya muunganisho) | approx. 16 ms |
| Ishara ya ingizo ya sasa (Hali za mazingira) | 0 mA ... 40 mA |
| Ishara ya kuingiza volteji (Hali ya mazingira) | 0 mV ... 1000 mV |
| Volti ya insulation iliyokadiriwa (Data ya muunganisho) | 50 V AC/DC |
| Jaribio la kuingiza/kutoa volteji (Data ya muunganisho) | 1.5 kV (50 Hz, 1 min.) |
| Halijoto ya mazingira (uendeshaji) (Vipimo) | -25 °C ... 70 °C |
| Pakia/toa pakia cha sasa (Data ya kuingiza) | < 1000 Ω ((UB- 8 V) / 22 mA) |
| Hitilafu ya juu zaidi ya uwasilishaji (Data ya muunganisho) | < 0.1 % (of final value) |
| Kizuizi cha matumizi (Data Muhimu za Kibiashara) | 1 |
| Cheti cha uainishaji (Data ya muunganisho) | DNV GL 14085-15HH |
| Sehemu ya juu ya kondakta AWG. (Ugavi wa umeme) | 12 |
| Sehemu ya chini ya AWG ya kondakta (Usambazaji wa umeme) | 24 |
| Utangamano wa sumaku-umeme (Data ya muunganisho) | Conformance with EMC directive |
| Upeo wa juu wa sehemu nzima ya kondakta. (Usambazaji wa umeme) | 2.5 mm² |
| Sehemu nzima ya kondakta kwa dakika 1. (Usambazaji wa umeme) | 0.2 mm² |
| Kiwango cha juu cha mgawo wa halijoto (Data ya muunganisho) | 0.01 %/K |
| Kipimo cha halijoto, cha kawaida (Data ya muunganisho) | 0.005 %/K |
| Ingizo la mkondo wa upinzani wa pembejeo (Hali za mazingira) | ≤ 50 Ω |
| Halijoto ya kawaida (uhifadhi/usafiri) (Vipimo) | -40 °C ... 85 °C |
| Kipeo cha juu kinachonyumbulika cha kondakta. (Usambazaji wa umeme) | 2.5 mm² |
| Sehemu ya chini inayonyumbulika ya kondakta (Usambazaji wa umeme) | 0.2 mm² |
| Upinzani wa pembejeo wa volteji (Hali za mazingira) | approx. 100 kΩ (At ≤ 1 V, otherwise approximately 1 MΩ) |
| Mkengeuko wa kawaida kutoka kwa thamani ya mwisho ya masafa ya kupimia (Jumla) | 0.5 % |
| Ulinzi wa moto kwa magari ya reli (DIN EN 45545-2) R22 (data ya EMC) | HL 1 - HL 2 |
| Ulinzi wa moto kwa magari ya reli (DIN EN 45545-2) R23 (data ya EMC) | HL 1 - HL 2 |
| Ulinzi wa moto kwa magari ya reli (DIN EN 45545-2) R24 (data ya EMC) | HL 1 - HL 2 |
| Ulinzi wa moto kwa magari ya reli (DIN EN 45545-2) R22 (Data ya muunganisho) | HL 1 - HL 2 |
| Ulinzi wa moto kwa magari ya reli (DIN EN 45545-2) R23 (Data ya muunganisho) | HL 1 - HL 2 |
| Ulinzi wa moto kwa magari ya reli (DIN EN 45545-2) R24 (Data ya muunganisho) | HL 1 - HL 2 |
Speci za kiufundi na data ya utendaji