| Kipengele | Thamani |
|---|---|
| 2 mA ... 22 mA (Function area) | |
| Mzigo | 0 Ω ... 600 Ω |
| Dokezo | With connection of measuring transducers |
| Kina | 113.7 mm |
| Upana | 17.5 mm |
| Urefu | ≤ 2000 m |
| Jumla | Installation conditions influence the ambient temperature.Please refer to the “Control cabinet installation instructions”. |
| Ishara ya kuingiza | Current |
| Aina ya bidhaa | Repeater power supplies |
| Uzi wa skrubu | M3 |
| Volti ya majaribio | 350 V (50 Hz, 60 s) |
| Ingizo la sasa | ≤ 50 mA (for mA sources) |
| Aina ya kupachika | NS 35/15, NS 35/7,5 |
| Utambulisho | II (1) G [Ex ia Ga] IIC |
| Familia ya bidhaa | MACX Analog |
| Onyesho la hali | Green LED (supply voltage) |
| Hitilafu ya mstari | ≤ 0.1 % |
| Idadi ya njia | 1 |
| Kina NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
| Nyenzo za makazi | Polyamide (PA 6.6) |
| Ingizo la sasa II | 100 mA |
| Volti ya kuingiza Ui | 30 V |
| Volti isiyo na mzigo | ≤ 26 V |
| Urefu wa kukatwa | 7 mm |
| Mbinu ya muunganisho | Screw connection |
| AWG ya sehemu mtambuka | (converted acc. to IEC) |
| Nafasi ya kupachika | vertical, horizontal |
| Matumizi ya nguvu | 2 W (20 mA) |
| Usambazaji wa nguvu | 1.5 W (RL250 Ω) |
| Maelezo ya matokeo | Current output (active) |
| Mchoro wa vipimo | |
| Saketi za Ex i (EPL) | Ga |
| Itifaki zinaungwa mkono | HART-transparent |
| Ishara ya sasa ya kuingiza data | 4 mA ... 20 mA (with HART) |
| Kiwango cha ulinzi | IP20 (Terminal blocks) |
| Kutengwa kwa umeme | 4-way isolation |
| Ugunduzi wa hitilafu ya mstari | < 3.6 mA (Line break) |
| Nguvu ya juu zaidi ya kutoa Po | 574 mW |
| Kiwango cha voltage ya usambazaji | 18 V ... 31.2 V |
| Hitilafu ya kawaida ya kukabiliana | ≤ 0.1 % |
| Ishara ya sasa ya kutoa | 4 mA ... 20 mA (with HART) |
| Usakinishaji wa awali (EPL) | Gc |
| Mkondo wa mzunguko mfupi | ≤ 35 mA |
| Viwango/kanuni | IEC/EN 60079-11 |
| Muda wa kawaida wa majibu | < 80 ms |
| Muda wa kawaida wa kuzima | < 100 ms |
| Aina ya ubadilishaji wa mguso | 2 N/O contacts |
| Kiwango cha juu cha pato la sasa Io | 87.9 mA |
| Volti ya juu zaidi ya kutoa Uo | 27 V |
| Mkondo wa kubadilisha wa kiwango cha juu zaidi | 100 mA |
| Volti ya usambazaji wa kawaida | 24 V DC |
| Ripple ya kutoa (mkondo) | ≤ 40 µA (effective) |
| Maelezo ya ingizo | active and passive current input, intrinsically safe |
| Volti ya insulation iliyokadiriwa | 375 VPP |
| Kiwango cha kupimia masafa | 0.5 kHz ... 10 kHz (bidirectional HART transmission) |
| Volti ya juu zaidi ya kubadili | 30 V |
| Sehemu ya msalaba ya kondakta AWG | 24 ... 14 |
| Kiwango cha juu cha upenyezaji wa ndani Li | negligible |
| Ulinzi wa polari ya nyuma | yes |
| Uwezo wa juu zaidi wa ndani Ci | negligible |
| Tabia ya upitishaji wa mawimbi | In = Out |
| Sehemu ngumu ya kondakta | 0.2 mm² ... 2.5 mm² |
| Utangamano wa sumakuumeme | Tested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21 |
| Ingizo la sasa la upinzani wa pembejeo | > 250 Ω (for mA sources) |
| Halijoto ya mazingira (uendeshaji) | -40 °C ... 70 °C (Stand-alone device: any mounting position) |
| Sehemu ya msalaba ya kondakta inayonyumbulika | 0.2 mm² ... 2.5 mm² |
| Unyevu unaoruhusiwa (uendeshaji) | ≤ 95 % (non-condensing) |
| Mgawo wa halijoto, wa kawaida | ≤ 0.1 % (10 K) |
| Volti ya juu inayohusiana na usalama Um | 253 V AC |
| Ukadiriaji wa kuwaka kulingana na UL 94 | V0 |
| Halijoto ya kawaida (uhifadhi/usafiri) | -40 °C ... 80 °C |
| IIC (mzunguko mchanganyiko): Upeo wa juu wa inductivity ya nje Lo/ Upeo wa juu wa uwezo wa nje Co | 1 mH / 56 nF, 0.5 mH / 72 nF, 0.2 mH / 90 nF |
| IIC (saketi rahisi): Upeo wa juu wa inductivity ya nje Lo/ Upeo wa juu wa uwezo wa nje Co | 2.3 mH / 90 nF |
| IIB/IIIC (mzunguko mchanganyiko): Upeo wa juu wa inductivity ya nje Lo/ Upeo wa juu wa uwezo wa nje Co | 10 mH / 290 nF, 1 mH / 380 nF, 0.2 mH / 600 nF |
| IIB/IIIC (saketi rahisi): Upeo wa juu wa inductivity ya nje Lo/ Upeo wa juu wa uwezo wa nje Co | 14 mH / 705 nF |
Speci za kiufundi na data ya utendaji
Mwongozo wa usakinishaji na uendeshaji