| Kipengele | Thamani |
|---|---|
| < 100 Ω ... 360 Ω (Short Circuit) | |
| Mzigo | 0 Ω ... 600 Ω |
| Kina | 113.7 mm |
| Upana | 17.5 mm |
| Urefu | ≤ 2000 m |
| Imetiwa alama | II (1) G [Ex ia Ga] IIC |
| Jumla | Accuracy, typical data in % of the basic measurement interval with UN, 23 °C |
| Muda wa Msukumo | 25 μs |
| Aina ya Bidhaa | Frequency value transformer |
| Volti ya majaribio | 350 V (50 Hz, 60 sec) |
| Usanidi | Software |
| Familia ya Bidhaa | MACX Analog |
| Nyenzo ya ganda | Polyamide (PA 6.6) |
| Volti ya usambazaji | 18 V ... 31.2 V |
| Aina ya muunganisho | Push-in connection |
| Kina NS 35/7.5 | 114.5 mm (fitted on DIN rail NS 35/7.5 according to EN 60715) |
| Mpango wa Vipimo | |
| Nguvu Iliyotoweka | ≤ 1.5 W |
| Kielezo cha Ulinzi | IP20 (Terminals) |
| Aina ya ufungaji | NS 35/15, NS 35/7.5 |
| Matumizi ya Nguvu | 1.8 W |
| Dalili ya Hali | Green LED (supply voltage) |
| Idadi ya njia | 2 |
| Maelezo ya Tiketi | Intrinsic safety |
| Utengano wa Galvaniki | 5-way spacing |
| Ugunduzi wa Hitilafu ya Mstari | < 0.05 mA ... 0.35 mA (Cable Break) |
| Vyanzo vya Ingizo Vinavyoweza Kutumika | According to IEC/EN 60947-5-6 NAMUR |
| Sehemu ya Kondakta wa AWG | (Converted according to IEC) |
| Ishara ya Matokeo ya Sasa | 0 mA ... 20 mA (configurable) |
| Usakinishaji wa Zamani (EPL) | Gc |
| Nguvu ya juu zaidi ya kutoa | 61.4 mW |
| Nafasi ya kupachika | vertical, horizontal |
| Volti ya Ugavi wa Majina | 24 V DC |
| Ior ya Sasa ya Pato la Juu | 23.4 mA |
| Volti ya juu zaidi ya kutoa Uor | 10.5 V |
| Sehemu ngumu ya kondakta | 0.2 mm² ... 1.5 mm² |
| Viwango/Vipimo | IEC/EN 60079-11 |
| Urefu wa kuondoa joto | 8 mm |
| Uwezo wa Ndani wa Juu Ci | despicable |
| Kiwango cha Juu cha Kubadilisha Volti | 30 V |
| Volti ya usalama ya juu zaidi Um | 253 V AC |
| Kiwango cha juu cha ubadilishaji wa sasa | 100 mA |
| Ukubwa wa Voltage ya Insulation | 375 VPP |
| Sehemu ya kondakta inayonyumbulika | 0.2 mm² ... 1.5 mm² |
| Kiwango cha upimaji wa masafa | 0.001 Hz ... 20000 Hz |
| Kiwango cha juu cha upenyezaji wa ndani. Li | despicable |
| Ulinzi wa kugeuza polarity | Yes |
| Halijoto ya Mazingira (Huduma) | -40 °C ... 70 °C (Individual Equipment: Discretionary Mounting Position) |
| Utangamano wa sumakuumeme | Testing according to the following standards and requirements: EN 61326-1 for use in the industrial field, NAMUR NE 21 |
| Kipimo cha Joto la Kawaida | ≤ 0.05% |
| Saketi salama za ndani (EPL) | Ga |
| Unyevu unaoruhusiwa wa hewa (huduma) | ≤ 95% (non-condensing) |
| Darasa la kuwaka kulingana na UL 94 | V0 |
| Halijoto ya Mazingira (Uhifadhi/Usafiri) | -40 °C ... 80 °C |
| Mkondo wa kutoa matokeo katika kesi ya mzunguko mfupi | 3.8 mA (Original Factory Settings, Adjustable) |
| Mkondo wa kutoa umeme iwapo kebo itavunjika | 20.5 mA (Original Factory Settings, Adjustable) |
| I (saketi moja ya umeme): Kiwango cha juu cha inductance ya nje. Kiwango cha juu/ Kiwango cha juu cha uwezo wa nje. Kor | 600 mH / 95 μF |
| I (saketi ya umeme iliyochanganywa): Upeo wa inductance ya nje. Lor/ Max. Uwezo wa nje Kor | 100 mH / 4 μF, 10 mH / 5.7 μF, 2 mH / 7.8 μF, 0.1 mH / 17 μF |
| IIA (Mzunguko Mmoja wa Umeme): Uingizaji wa nje wa kiwango cha juu zaidi. Lor/ Max. uwezo wa nje Kor | 450 mH / 75 μF |
| IIC (Mzunguko Mmoja wa Umeme): Uingizaji wa nje wa kiwango cha juu zaidi. Lor/ Max. uwezo wa nje Kor | 63 mH / 2.41 μF |
| IIA (Mzunguko wa Umeme Mchanganyiko): Uingizaji wa nje wa kiwango cha juu zaidi. Lor/ Max. uwezo wa nje Kor | 100 mH / 2.9 μF, 10 mH / 4.5 μF, 1 mH / 7.3 μF, 0.1 mH / 14 μF |
| IIC (Mzunguko wa Umeme Mchanganyiko): Uingizaji wa nje wa kiwango cha juu zaidi. Lor/ Max. uwezo wa nje Kor | 20 mH / 0.49 μF, 5 mH / 0.67 μF, 1 mH / 0.96 μF, 0.2 mH / 1.4 μF |
| IIB/IIIC (Mzunguko Mmoja wa Umeme): Uingizaji wa Nje wa Kiwango cha Juu cha Lori/ Kiwango cha Juu cha Uwezo wa Nje wa Cor | 230 mH / 16.8 μF |
| IIB/IIIC (Mzunguko wa Umeme Mchanganyiko): Uingizaji wa nje wa kiwango cha juu zaidi. Lor/ Kiwango cha juu zaidi cha uwezo wa nje. Kor | 100 mH / 1.9 μF, 20 mH / 2.7 μF, 2 mH / 4.5 μF, 0.5 mH / 6.4 μF |
Speci za kiufundi na data ya utendaji
Mwongozo wa usakinishaji na uendeshaji