Muda wa huduma: Jumatatu hadi Ijumaa 9:00-18:00
ILC 370 PN 2TX-IB - ILC 370 PN 2TX-IB 2876915 PHOENIX CONTACT Inline Controller with PROFINET interfaces for coupling to other c..
Kipatikana Bidhaa Maarufu

ILC 370 PN 2TX-IB

ILC 370 PN 2TX-IB 2876915 PHOENIX CONTACT Inline Controller with PROFINET interfaces for coupling to other c..

$0.00USD
4363 kwenye hisa
Vipimo Muhimu
:max. 512 Bit (INTERBUS-Slave)
Kina:71.5 mm
Mshtuko:25g, Criterion 1, according to IEC 60068-2-27
Upana:182 mm
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
max. 512 Bit (INTERBUS-Slave)
Kina71.5 mm
Mshtuko25g, Criterion 1, according to IEC 60068-2-27
Upana182 mm
Urefu140.5 mm
Uzito440 g
KiolesuraINTERBUS local bus (master)
Jina la kuingizaDigital inputs
Jina la matokeoDigital outputs
Kiwango cha sasishomin. 1 ms
Hifadhi ya wingi4 Mbyte
VipimoVersion 1.1
Kumbukumbu ya programutyp. 2 Mbyte (170 K instructions (IL))
Saa ya wakati halisiIntegrated (battery backup)
Volti ya usambazaji24 V DC ±5 %
Kipengele cha kifaaPROFINET-IO controller
Mabaki ya mawimbi± 5 %
Zana ya utambuziDIAG+ from version 1.14
Idadi ya pembejeo12
Zana ya programuPC WORX
Mbinu ya muunganishoInline data jumper
Idadi ya matokeo4
Usambazaji wa nguvumax. 6 W
Kasi ya upitishaji500 kBaud / 2 MBaud (can be switched)
Onyesho la uchunguziNo
Kiwango cha ulinziIP20
Kiwango cha voltage ya usambazaji20.4 V DC ... 30 V DC
Bila ingizo la analogiyes
Upungufu wa kidhibitiNo
Mtetemo (uendeshaji)5g, accordance to IEC 60068-2-6
Bila matokeo ya analogiyes
Bila pembejeo ya kukanushayes
Kiasi cha data ya mchakatomax. 8192 Bit (INTERBUS-Master)
Hifadhi ya wingi iliyobaki96 kByte (NVRAM)
Idadi ya kazi za udhibiti16
Shinikizo la hewa (uendeshaji)70 kPa ... 106 kPa (up to 3000 m above sea level)
Maelezo ya ingizoEight fast inputs, interrupt input
Idadi ya vifaa vinavyotumikamax. 512 (in total, of which 254 are remote bus devices/bus segments)
Matumizi ya kawaida ya sasa250 mA (no local bus device connected during idling, bus inactive)
Bila mwelekeo wa mapigoyes
Halijoto ya mazingira (uendeshaji)-25 °C ... 55 °C
Shinikizo la hewa (uhifadhi/usafiri)70 kPa ... 106 kPa (up to 3000 m above sea level)
Unyevu unaoruhusiwa (uendeshaji)10 % ... 95 % (non-condensing)
Kiwango cha juu cha pato la sasa kwa kila chaneli500 mA
Halijoto ya kawaida (uhifadhi/usafiri)-25 °C ... 85 °C
Idadi ya vifaa vyenye chaneli ya vigezomax. 62
Unyevu unaoruhusiwa (uhifadhi/usafiri)10 % ... 95 % (non-condensing)
Idadi ya vifaa vya basi vya ndani vinavyoweza kuunganishwamax. 63 (observe current consumption)
Idadi ya vituo vya matawi vinavyoungwa mkono vyenye tawi la basi la mbalimax. 15

Maelezo ya Bidhaa

More details
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Maelezo ya Kiufundi

With the ILC 370 PN 2TX-IB, the highly modular Inline Controller range from Phoenix Contact has been extended to include a high-performance PROFINET controller. This controller can be used to extend the field of application of Inline Controllers through to medium-sized applications. With direct integration in the Inline automation system, the compact controller is highly modular and can be adapted to the relevant application requirements. Its integrated PROFINET interfaces enable parameterization and programming using PC WorX automation software according to IEC 61131, and it can also exchange data with OPC servers simultaneously and communicate with TCP/IP-compatible devices.

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji

Top