| Kipengele | Thamani |
|---|---|
| GTIN | 4046356095259 |
| Dokezo | Made to Order (non-returnable) |
| Ufunguo wa kuagiza | 1636884 |
| Ukurasa wa katalogi | Page 551 (C-4-2015) |
| Kitengo cha kufungasha | 1 pc |
| Nchi ya asili | DE (Germany) |
| Nambari ya ushuru maalum | 85366990 |
| (Hali ya mazingira) | 16 mm (70 mm²) |
| Nyenzo za mawasiliano (Jumla) | Copper alloy |
| Mkondo uliokadiriwa (Vipimo) | 200 A |
| Upana (Data Muhimu ya Biashara) | 34.2 mm |
| Urefu (Data Muhimu ya Kibiashara) | 29.4 mm |
| Wasifu wa muunganisho (Vipimo) | 1 |
| Volti ya kuongezeka iliyokadiriwa (Vipimo) | 8 kV |
| Nyenzo za mtoa huduma za mawasiliano (Jumla) | PC |
| Nyenzo ya uso wa mguso (Jumla) | Ag |
| Volti iliyokadiriwa (III/3) (Vipimo) | 1000 V |
| Mfululizo (Sifa za kiufundi) | HC-M-HS |
| Uzito kwa Kipande (bila kujumuisha upakiaji) | 70.400 g |
| Soketi ya hexagonal (Hali ya mazingira) | WAF 5 |
| Kukaza torque (Hali ya mazingira) | 9 Nm (40 - 50 mm²) |
| Muunganisho (Sifa za kiufundi) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The wires should be inserted as far as they will go in the contact chamber (until the insulation touches the contact). Hold wires in position and use socket wrench to tighten. The used wire end should be cut off before connecting again. The connection screw may only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable should be mechanically intercepted at an appropriate distance from the connection point (e.g., by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. The module cannot be used simultaneously with the HC-B..-TMB-SD-IP65 and HC-B..-TMS-SD-IP65 protective covers. |
| Urefu wa chini kabisa wa makazi (Hali ya mazingira) | 72 mm |
| Sehemu ya msalaba ya kondakta (Hali ya mazingira) | 40 mm² ... 70 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Mbinu ya muunganisho (Sifa za kiufundi) | Axial screw connection |
| Muunganisho katika akaunti na (Data ya nyenzo) | UL |
| Kiwango cha uchafuzi (Sifa za kiufundi) | 3 |
| Mizunguko ya kuingiza/kutoa (Hali za mazingira) | ≥ 500 |
| Sehemu ya muunganisho AWG (Hali za mazingira) | 1 ... 00 |
| Kategoria ya overvoltage (Sifa za mitambo) | III |
| Maagizo ya uunganishaji (Sifa za kiufundi) | - Use only flexible conductors,- Connection of wires with 5 mm an Allen wrench,- Housing height h ≥ 72 mm,- Connectors may only be operated without load/voltage. |
| Idadi ya nafasi za moduli (Sifa za kiufundi) | 2 |
| Ukadiriaji wa kuwaka kulingana na UL 94 (Data ya nyenzo) | V0 |
| Kipenyo cha waya ikijumuisha insulation (Hali ya mazingira) | 12 mm (40 mm²) |
| Halijoto ya mazingira (uendeshaji) (Sifa za umeme) | -40 °C ... 125 °C |
| Urefu wa kukatwa kwa waya mmoja mmoja (Hali ya mazingira) | 16 mm |
| Ukadiriaji wa kuwaka kulingana na UL 94 (Sifa za kiufundi) | V0 |
Speci za kiufundi na data ya utendaji
Mwongozo wa usakinishaji na uendeshaji