Vipimo Muhimu
:Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly.
Upana:34.2 mm
Urefu:14.6 mm
Mfululizo:HC-M-02
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly.
Upana34.2 mm
Urefu14.6 mm
MfululizoHC-M-02
JumlaFor HEAVYCON housing type B6 to B48, HC-M-MHR... hinged retaining frame required
MaombiPower
Aina ya bidhaaModular contact insert
Dokezo la mkutano- Connection of the wires using a 2 mm Allen wrench.- Housing height ≥ 52 mm.- Axial screw connection only for flexible wires.- Plug-in connections may only be operated only when there is no load/voltage.
Imekadiriwa mkondo40 A
Nyenzo ya mawasilianoCopper alloy
Soketi ya hexagonalSW 2
Nambari za mawasiliano1 - 2
Kukaza torque1.5 Nm (2.5 mm² ... 4 mm²)
Wasifu wa muunganisho2
Kiwango cha uchafuzi wa mazingira3
Mchoro wa vipimo
Idadi ya nafasi2
Volti ya kuongezeka iliyokadiriwa8 kV
Kategoria ya volteji nyingiIII
Teknolojia ya muunganishoAxial screw connection
Volti iliyokadiriwa (III/3)1000 V
Idadi ya nafasi za moduli1
Sehemu ya msalaba ya kondakta2.5 mm² ... 8 mm² (The cross section specification refers to the geometric cross section of the cable used)
Nyenzo za mawasilianoPC
Nyenzo ya uso wa mgusoAg
Mizunguko ya kuingiza/kutoa≥ 500
Sehemu ya muunganisho AWG12 ... 10
Halijoto ya mazingira (uendeshaji)-40 °C ... 125 °C
Muunganisho katika acc. na kiwango cha kawaidaIEC / EN
Ukadiriaji wa kuwaka kulingana na UL 94V0
Urefu wa kukatwa kwa waya mmoja mmoja8 mm +1 mm (for 6 mm²)