HC-M-02-HS-70/16-MOD-ST - HC-M-02-HS-70/16-MOD-ST 1585702 PHOENIX CONTACT Contact insert module
Kipatikana Bidhaa Maarufu

HC-M-02-HS-70/16-MOD-ST

HC-M-02-HS-70/16-MOD-ST 1585702 PHOENIX CONTACT Contact insert module

$0.00USD
4734 kwenye hisa
Vipimo Muhimu
GTIN:4046356308205
Dokezo:Made to Order (non-returnable)
Ufunguo wa kuagiza:1585702
Ukurasa wa katalogi:Page 553 (C-4-2015)
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
GTIN4046356308205
DokezoMade to Order (non-returnable)
Ufunguo wa kuagiza1585702
Ukurasa wa katalogiPage 553 (C-4-2015)
Kitengo cha kufungasha2 pc
Nchi ya asiliDE (Germany)
Nambari ya ushuru maalum85366990
(Hali ya mazingira)4 Nm (16 mm²)
Kiasi cha chini cha oda2 pc
Nyenzo za mawasiliano (Jumla)Copper alloy
Mkondo uliokadiriwa (Vipimo)70 A
Upana (Data Muhimu ya Biashara)34.2 mm
(Viwango na Kanuni)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Urefu (Data Muhimu ya Kibiashara)14.6 mm
Wasifu wa muunganisho (Vipimo)2
Volti ya kuongezeka iliyokadiriwa (Vipimo)8 kV
Nyenzo za mtoa huduma za mawasiliano (Jumla)PC
Nyenzo ya uso wa mguso (Jumla)Ag
Volti iliyokadiriwa (III/3) (Vipimo)1000 V
Mfululizo (Sifa za kiufundi)HC-M-HS
Uzito kwa Kipande (bila kujumuisha upakiaji)32.180 g
Soketi ya hexagonal (Hali ya mazingira)SW2,5
RoHS ya China (Viwango na Kanuni)Environmentally Friendly Use Period = 50
Kukaza torque (Hali ya mazingira)2 Nm (6 mm² )
Muunganisho (Sifa za kiufundi)Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Urefu wa chini kabisa wa makazi (Hali ya mazingira)72 mm
Sehemu ya msalaba ya kondakta (Hali ya mazingira)6 mm² ... 16 mm²
Mbinu ya muunganisho (Sifa za kiufundi)Axial screw connection
Muunganisho katika akaunti na (Data ya nyenzo)UL
Kiwango cha uchafuzi (Sifa za kiufundi)3
Mizunguko ya kuingiza/kutoa (Hali za mazingira)≥ 500
Sehemu ya muunganisho AWG (Hali za mazingira)8 ... 6
Kategoria ya overvoltage (Sifa za mitambo)III
Maagizo ya uunganishaji (Sifa za kiufundi)Use 2.5 mm Allen wrenches for axial connection. Only for stranded wires. For housing heights h ≥ 52 mm. Plug-in connections may only be operated only when there is no load/voltage.
Idadi ya nafasi za moduli (Sifa za kiufundi)1
Ukadiriaji wa kuwaka kulingana na UL 94 (Data ya nyenzo)V0
Kipenyo cha waya ikijumuisha insulation (Hali ya mazingira)8.9 mm
Halijoto ya mazingira (uendeshaji) (Sifa za umeme)-40 °C ... 125 °C
Urefu wa kukatwa kwa waya mmoja mmoja (Hali ya mazingira)11 mm +1
Ukadiriaji wa kuwaka kulingana na UL 94 (Sifa za kiufundi)V0