Muda wa huduma: Jumatatu hadi Ijumaa 9:00-18:00
HC-M-02-CT-M-HV-16 - HC-M-02-CT-M-HV-16 1417408 PHOENIX CONTACT Module inserts contacts HEAVYCON male, 2-pole, up to 5000 V, conn..
Kipatikana Bidhaa Maarufu

HC-M-02-CT-M-HV-16

HC-M-02-CT-M-HV-16 1417408 PHOENIX CONTACT Module inserts contacts HEAVYCON male, 2-pole, up to 5000 V, conn..

$0.00USD
3994 kwenye hisa
Vipimo Muhimu
:Assembly procedure:- Strip wire 9.5 mm,- connect the stripped part of the wire through the locking sleeve (for wire diameter > 3.2 mm),- crimp wire (with protracted locking sleeve) with CK2.5...ED crimp contact,- lock the locking sleeve with the crimp contact together with the module's insulating body.
Upana:34.1 mm
Urefu:29.3 mm
Mfululizo:HC-M-HV
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
Assembly procedure:- Strip wire 9.5 mm,- connect the stripped part of the wire through the locking sleeve (for wire diameter > 3.2 mm),- crimp wire (with protracted locking sleeve) with CK2.5...ED crimp contact,- lock the locking sleeve with the crimp contact together with the module's insulating body.
Upana34.1 mm
Urefu29.3 mm
MfululizoHC-M-HV
JumlaFor HEAVYCON housing type B6 to B48, HC-M-B...MF-... hinged module carrier frame required, CK2,5-ED... imp contacts, crimp contacts not supplied as standard.
MaombiHigh-voltage
Aina ya bidhaaModular contact insert
Dokezo la mkutanoTo ensure correct use, installation in housing with IP54 protection or better is required
Imekadiriwa mkondo16 A
Marekebisho ya makala04
Kipenyo cha mguso2.5 mm
Nyenzo ya mawasilianoCopper alloy
Nambari za mawasilianoI, II
Wasifu wa muunganisho2
Kiwango cha uchafuzi wa mazingira3
Mchoro wa vipimo
Idadi ya nafasi2
Volti ya kuongezeka iliyokadiriwa15 kV
Kategoria ya volteji nyingiIII
Teknolojia ya muunganishoCrimp connection
Aina ya nyenzo za mgusoturned
Idadi ya mawasiliano ya umeme2
Volti iliyokadiriwa (III/3)2900 V (Conductor-PE)
Viwango/kanuniPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Urefu wa chini kabisa wa nyumba72 mm
Idadi ya nafasi za moduli2
Sehemu ya msalaba ya kondakta0.5 mm² ... 4 mm²
Idadi ya mawasiliano ya udhibiti0
Nyenzo za mawasilianoPC
Nyenzo ya uso wa mgusoAg (alternatively Au)
Mizunguko ya kuingiza/kutoa≥ 500
Sehemu ya muunganisho AWG20 ... 12
Halijoto ya mazingira (uendeshaji)-40 °C ... 125 °C
Volti iliyokadiriwa kwa mawasiliano ya nguvu2900/5000 V
Ukadiriaji wa kuwaka kulingana na UL 94V0
Urefu wa kukatwa kwa waya mmoja mmoja9.5 mm

Maelezo ya Bidhaa

Contact insert module, number of poles: 2, power contacts: 2, control contacts: 0, Male, Crimped connection, 2900 V/5000 V, 16 A, 0.5 mm² ... 4 mm², application: High voltage
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji

Top