Muda wa huduma: Jumatatu hadi Ijumaa 9:00-18:00
HC-M-02-AT-F-25 - HC-M-02-AT-F-25 1421378 PHOENIX CONTACT Module inserts contact HC-M-02-AT-F-25 1421378
Kipatikana Bidhaa Maarufu

HC-M-02-AT-F-25

HC-M-02-AT-F-25 1421378 PHOENIX CONTACT Module inserts contact HC-M-02-AT-F-25 1421378

$0.00USD
3215 kwenye hisa
Vipimo Muhimu
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Jumla:For HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
Maombi:Power
Imekadiriwa mkondo:100 A
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
JumlaFor HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
MaombiPower
Imekadiriwa mkondo100 A
Kiwango cha uchafuzi wa mazingira3
Idadi ya nafasi2
Volti ya kuongezeka iliyokadiriwa8 kV
Kategoria ya volteji nyingiIII
Maagizo ya kusanyikoTo ensure correct use, installation in housing with IP54 protection or better is required
Volti iliyokadiriwa (III/3)1000 V
Ukadiriaji wa kuwaka kulingana na UL 94V0
Urefu wa kukatwa kwa waya mmoja mmoja13 mm

Maelezo ya Bidhaa

Contact insert module, Socket, Axial screw connection, 1000 V, 100 A, 10 mm2 ... 25 mm2, application: Power
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji

Top