| Kipengele | Thamani |
|---|---|
| Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. | |
| Aina | B16 |
| Upana | 34 mm |
| Urefu | 84.5 mm |
| Mfululizo | HC-K |
| Jumla | For HEAVYCON ADVANCE and HEAVYCON housing of type B16/B32, axial connection for 2 mm Allen wrench |
| Maombi | Power/signal |
| Aina ya bidhaa | Contact insert with a fixed no. of positions |
| Dokezo la mkutano | To ensure correct use, installation in housing with IP54 protection or better is required |
| Imekadiriwa mkondo | 40 A (power contacts) |
| Marekebisho ya makala | 04 |
| Kipenyo cha mguso | 4 mm |
| Nyenzo ya mawasiliano | Cu alloy |
| Nambari za mawasiliano | 1 - 6 (power contacts) |
| Kisu cha bisibisi | 0.5 x 3.5 mm (control contacts) |
| Kukaza torque | 2 Nm ... 2.5 Nm (PE connection) |
| Wasifu wa muunganisho | 6+12+PE |
| Kiwango cha uchafuzi wa mazingira | 3 |
| Mchoro wa vipimo | |
| Idadi ya nafasi | 18 |
| Volti ya kuongezeka iliyokadiriwa | 8 kV (power contacts) |
| Kategoria ya volteji nyingi | III |
| Teknolojia ya muunganisho | Axial screw connection (power contacts) |
| Aina ya nyenzo za mguso | turned |
| Idadi ya mawasiliano ya umeme | 6 |
| Volti iliyokadiriwa (III/3) | 690 V |
| Sehemu ya msalaba ya kondakta | 2.5 mm² ... 10 mm² (power contacts) |
| Idadi ya mawasiliano ya udhibiti | 12 |
| Nyenzo za mawasiliano | PC |
| Mizunguko ya kuingiza/kutoa | ≥ 500 |
| Sehemu ya muunganisho AWG | 12 ... 8 (power contacts) |
| Halijoto ya mazingira (uendeshaji) | -40 °C ... 125 °C |
| Umbali wa kuchimba shimo, mlalo | 77.5 mm |
| Volti iliyokadiriwa kwa mawasiliano ya nguvu | 230/400 V |
| Ukadiriaji wa kuwaka kulingana na UL 94 | V0 |
| Urefu wa kukatwa kwa waya mmoja mmoja | 8 mm +1 mm (Power 6 mm² ... 10 mm²) |
| Nyenzo ya uso wa mguso, mguso wa nguvu | Ag |
| Nyenzo ya uso wa mguso, mguso wa kudhibiti | Ag |
Speci za kiufundi na data ya utendaji
Mwongozo wa usakinishaji na uendeshaji