HC-HS 2-D7-EBUS - HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert
Kipatikana Bidhaa Maarufu

HC-HS 2-D7-EBUS

HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert

$35.46USD
326 kwenye hisa
Vipimo Muhimu
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Aina:D7
Majaribio:DIN VDE 0627/86
Upana:21 mm
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
AinaD7
MajaribioDIN VDE 0627/86
Upana21 mm
Urefu21 mm
MfululizoHC-HS
Jumlafor HC-D7 housing, axial connection 2.0 mm, Allen key
MaombiPower
Aina ya bidhaaContact insert with a fixed no. of positions
Dokezo la mkutanoTo ensure correct use, installation in housing with IP54 protection or better is required
Imekadiriwa mkondo40 A
Marekebisho ya makala04
Kipenyo cha mguso4 mm
Nyenzo ya mawasilianoCopper alloy
Soketi ya hexagonalSW2,0
Nambari za mawasiliano1 - 2
Kukaza torque0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Wasifu wa muunganisho2+PE
Kiwango cha uchafuzi wa mazingira3
Mchoro wa vipimo
Idadi ya nafasi2
Volti ya kuongezeka iliyokadiriwa6 kV
Kategoria ya volteji nyingiIII
Teknolojia ya muunganishoAxial screw connection
Aina ya nyenzo za mgusoturned
Idadi ya mawasiliano ya umeme2
Volti iliyokadiriwa (III/3)400 V
Sehemu ya msalaba ya kondakta4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used)
Nyenzo za mawasilianoPC
Nyenzo ya uso wa mgusoAg
Mizunguko ya kuingiza/kutoa≥ 500
Sehemu ya muunganisho AWG10 ... 8
Halijoto ya mazingira (uendeshaji)-40 °C ... 125 °C (including heating up of contacts)
Muunganisho katika acc. na kiwango cha kawaidaIEC / EN
Kanuni za ujenzi na upimajiDIN VDE 0627/86
Ukadiriaji wa kuwaka kulingana na UL 94V0
Urefu wa kukatwa kwa waya mmoja mmoja8 mm +1 mm

Maelezo ya Bidhaa

Contact insert, number of poles: 2+PE, size: D7, power contacts: 2, Female, Axial screw connection, 400 V, 40 A, 4 mm² ... 10 mm², Application: Power
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji

Top