| Kipengele | Thamani |
|---|---|
| GTIN | 4046356092340 |
| Ufunguo wa kuagiza | 1648212 |
| Ukurasa wa katalogi | Page 537 (C-2-2017) |
| Kitengo cha kufungasha | 1 pc |
| Nchi ya asili | CN (China) |
| Nambari ya ushuru maalum | 85366990 |
| (Hali ya mazingira) | PA: Fire protection in rail vehicles - requirement set R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| (Data Muhimu za Kibiashara) | Connectors may be operated only when there is no load/voltage. |
| Dokezo (Data Muhimu ya Kibiashara) | For HEAVYCON ADVANCE and HEAVYCON housing of B10 type, crimp contacts CK 2,5-ED (crimp contacts not included in the scope of supply). |
| Ukubwa (Data Muhimu ya Kibiashara) | B10 |
| (Viwango na Kanuni) | No hazardous substances above threshold values |
| (Sifa za umeme) | IEC 60352 |
| Mkondo uliokadiriwa (Data ya nyenzo) | 16 A |
| Muunganisho (Data Muhimu ya Biashara) | For housing type B10. Connectors may only be inserted when there is no load/the power is switched off. Use a screwdriver to remove the crimp contacts. The opening for the screwdriver is next to the opening where the conductor is inserted. |
| Degree of protection (IP) (General) | IP20 |
| Volti ya kuongezeka iliyokadiriwa (Data ya nyenzo) | 6 kV |
| Uzito kwa Kipande (bila kujumuisha upakiaji) | 46.200 g |
| Nyenzo ya mguso (Hali ya mazingira) | Copper alloy |
| Volti iliyokadiriwa (III/3) (Data ya nyenzo) | 500 V |
| RoHS ya China (Viwango na Kanuni) | Environmentally friendly use period: unlimited = EFUP-e |
| Mbinu ya muunganisho (Data Muhimu ya Biashara) | Crimp connection |
| Nambari za mawasiliano (Data Muhimu za Biashara) | 1 - 10 |
| Halijoto ya mazingira (uendeshaji) (Jumla) | -40 °C ... 125 °C (including heating up of contacts) |
| Kiwango cha uchafuzi wa mazingira (Takwimu Muhimu za Kibiashara) | 3 |
| Idadi ya nafasi (Takwimu Muhimu za Kibiashara) | 10+PE |
| Kategoria ya overvoltage (Data Muhimu ya Biashara) | III |
| Viwango/kanuni (Mazingira ya Mazingira) | PA: Fire protection in rail vehicles - requirement sets R22 and R23 acc. to DIN EN 45545-2 (Risk level HL1 - HL2) |
| Maagizo ya uunganishaji (Data Muhimu ya Kibiashara) | To ensure correct use, installation in housing with IP54 protection or better is required |
| Sehemu ya msalaba ya kondakta (Data Muhimu ya Biashara) | 0.5 mm² ... 4 mm² |
| Nyenzo ya mtoa huduma ya mawasiliano (Hali ya mazingira) | PA |
| Nyenzo ya uso iliyogusana (Hali ya mazingira) | Ag (alternatively Au) |
| Mizunguko ya kuingiza/kutoa (Data Muhimu ya Biashara) | ≥ 500 |
| Sehemu ya muunganisho AWG (Data Muhimu ya Biashara) | 20 ... 12 |
| Idadi ya miunganisho kwa kila nafasi (Data Muhimu ya Biashara) | 1 |
| Muunganisho katika acc. na kiwango (Sifa za umeme) | CSA |
| Urefu wa kukatwa kwa waya mmoja mmoja (Data Muhimu ya Biashara) | 7.5 mm |
| Kanuni za ujenzi na upimaji (Sifa za umeme) | DIN EN 61984 |
| Ukadiriaji wa kuwaka kulingana na UL 94 (Sifa za umeme) | V0 |
Speci za kiufundi na data ya utendaji
Mwongozo wa usakinishaji na uendeshaji