| Kipengele | Thamani |
|---|---|
| PoDL Power Class 11 | |
| MTTF | 185.12 Years (SN 29500 standard, temperature 25 °C, duty cycle 21%) |
| Kina | 119 mm |
| Upana | 45 mm |
| Urefu | 130 mm |
| Jumla | Telephone and on-site support (for a fee) |
| Usimamizi | Web-based management (HTTP/HTTPS) |
| Upungufu wa Uzito | MRP (Media Redundancy Protocol) |
| LED za mawimbi | Data Receiving, Link Status |
| Ujenzi | Sample book |
| Aina ya Bidhaa | Switch |
| Kuchelewa kwa Mawimbi | ≥ 1.9 μs (Store-and-Forward mode, 10/100/1000 MBit/s, depending on frame size) |
| Volti ya majaribio | 500 V DC |
| Usalama wa Bandari | MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass |
| Familia ya Bidhaa | Managed Switch 2000 |
| Nyenzo ya ganda | Fiber-reinforced polycarbonate |
| Volti ya usambazaji | 20 V DC ... 32 V DC |
| Aina ya muunganisho | RJ45 |
| Utambuzi wa ndani | US1/2 Supply Voltage US1, US2 Green LED |
| Kazi Nyingine | MMS & GOOSE Transmission (IEC 61850-8-1) |
| Mabaki ya mawimbi | 3.6 VPP(within the permissible voltage range) |
| Mpango wa Vipimo | |
| Kazi za Kichujio | Quality of Service (8 priority classes) |
| Muunganisho wa umeme | via COMBICON, max. conductor cross-section 1.5 mm² |
| Kielezo cha Ulinzi | IP20 |
| Vipengele Maalum | Extended temperature range, Single Pair Ethernet ports with PoDL |
| Aina ya ufungaji | Rail mounting |
| Jedwali la Anwani za MAC | 8k |
| Matumizi ya Nguvu | 65 W (Vin= max, tAMB= Max, IPSE= 8x IPoDLmax, 100% data traffic on all connected ports) |
| Dalili ya Hali | LEDs: US1, US2 (Power Supply), Fail (Alarm Contact), 2 LEDs for each Ethernet port (Link/Activity and Speed) |
| Njia ya uthibitishaji | 1 minute at FE 500 V DC |
| Aina ya ulinzi | III (VDE 0106) |
| Idadi ya njia | 3 (RJ45 ports) |
| Kasi ya upitishaji | 10/100/1000 MBit/s |
| Utendaji Msingi | Switch Store and Forward, IEEE 802.3 compliant |
| Kiwango cha uchafuzi wa mazingira | 2 |
| Vigezo vya IP | DHCP-Client |
| Volti ya usambazaji (DC) | 24 V DC (Simultaneous PoDL power supply according to IEEE 802.3cg) |
| Urefu wa Usafirishaji | 100 m (per segment) |
| Kiwango cha Usambazaji | copper |
| Mtetemo (huduma) | according to IEC 60068-2-6: 5g, 150 Hz |
| Ajali (zinafanyika) | 30g (EN 60068-2-27) |
| Kazi za utambuzi | RMON History |
| Usawazishaji wa Wakati | SNTP (Simple Network Time Protocol) |
| Fizikia ya Uhamisho | copper |
| Sehemu ya Kondakta wa AWG | 24 ... 16 |
| Uchafuzi wa kuingiliwa | EN 61000-6-4 |
| Shinikizo la Hewa (Huduma) | 80 kPa ... 110 kPa up to 2000 m above sea level (No derating) |
| Upinzani wa kuingiliwa | EN 61000-6-2 |
| Sehemu ngumu ya kondakta | 0.25 mm² ... 1.5 mm² |
| Urefu wa kuondoa joto | 9 mm |
| Darasa la ulinganifu wa PROFINET | Conformance-Class B |
| Sehemu ya kondakta inayonyumbulika | 0.25 mm² ... 1.5 mm² |
| Kiwango cha Juu cha Kunyonya kwa Sasa | 2.2 A (Us= Min, TAMB= Max, SPE = 8x max. PoDL Power, 100% data traffic on all connected ports) |
| Ufyonzaji wa Kawaida wa Mkondo | 1.03 A (to Us= Nom, TAMB= 25°C, SPE = 4x max. PoDL Power, 100% data traffic on all connected ports) |
| Halijoto ya Mazingira (Huduma) | -40 °C ... 70 °C |
| Utangamano wa sumakuumeme | Compliance with EMC Directive 2014/30/EU |
| Kuzingatia maagizo ya EMC | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
| Kumbuka kuhusu aina ya muunganisho | Autonegoation and Autocrossing |
| Kazi ya moduli ya PROFINET | PROFINET Device |
| Shinikizo la Hewa (Uhifadhi/Usafiri) | 79 kPa ... 108 kPa up to 2000 m above sea level (No derating) |
| Hali na Dalili za Utambuzi | LEDs: US1, US2 (Power Supply), Fail (Alarm Contact), 2 LEDs for each Ethernet port (Link/Activity and Speed) |
| Unyevu unaoruhusiwa wa hewa (huduma) | 10 % ... 95% (non-condensing) |
| Halijoto ya Mazingira (Uhifadhi/Usafiri) | -40 °C ... 85 °C |
| Unyevu unaoruhusiwa wa hewa (uhifadhi/usafiri) | 10 % ... 95% (non-condensing) |
| Haina vitu vinavyosumbua vinavyolowesha varnish | Yes |
| Nguvu ya Juu Iliyosafishwa na Hali ya Majina | 12 W (Vin= max, tAMB= Max, IPSE= 8x IPoDLmax, 100% data traffic on all connected ports) |
Speci za kiufundi na data ya utendaji
Mwongozo wa usakinishaji na uendeshaji