FDQDB3M/6 - FDQDB3M/6 431078 GENERAL ELECTRIC FD-RCD DiffBottom-3p 220-440V AC
Kipatikana Bidhaa Maarufu

FDQDB3M/6

FDQDB3M/6 431078 GENERAL ELECTRIC FD-RCD DiffBottom-3p 220-440V AC

$0.00USD
3935 kwenye hisa
Vipimo Muhimu
Hali:Active
TOZO 5.0 (VIWANGO):EC001021
TOZO 6.0 (VIWANGO):EC001021
Uzito (MAELEZO):0.5 kg
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
HaliActive
TOZO 5.0 (VIWANGO)EC001021
TOZO 6.0 (VIWANGO)EC001021
Uzito (MAELEZO)0.5 kg
Masafa (HALI YA ODA/UTOAJI)Protection
Mfululizo (HALI YA AGIZO/UFIKIAJI)Residual Current devices
Aina ya Fremu (HALI YA AGIZO/UTOAJI)D frame (63A/160A)
Vipimo (HALI YA ODA/UTOAJI)87x81x85 mm
Idadi ya nguzo (HALI YA ODA/UTOAJI)3P
Maelezo ya Kiambatisho (HALI YA ODA/UTOAJI)Differential bottom
Ufungashaji wa kawaida (HALI YA ODA/UFIKIAJI)1

Maelezo ya Bidhaa

FDQDB3M/6
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Maelezo ya Kiufundi

A record plus circuit breaker can offer protection against earth leakage currents by using an add-on residual current device (RCD). A line of three pole completely integrated add-on devices are available as side mounted models (FD frame size) or as units that are fitted below the trip unit of the breaker (FD, FE and FG frame sizes). In all cases the RCD unit interfaces directly with the circuit breaker without the use of any secondary wiring connections. Earth RCD has a sensor placed around the phase and neutral current paths that detects the vectorial sum of the phase and neutral currents. When this sum is no longer zero it is assumed that current is flowing to earth (residual current). If this value exceeds the threshold set on the RCD the breaker connected to the device is tripped.The RCD units electrical power is supplied by the line voltage of the breaker it is linked to. By use of a multi-phase bridge the design still works when one phase and the neutral is present. A pouch on the RCD allows one to place one BAT contact NO or NC which allows a remote signal on earth faults. A Record Plus breaker and an RCD combination can be connected like any stand-alone breaker and are available as fixed or plug-in devices. The mains connection interface of the RCD is an exact replica of the breaker connection area, thus allowing the use of all standard breaker terminals.