Muda wa huduma: Jumatatu hadi Ijumaa 9:00-18:00
ELR H3-IS-PT-24DC/500AC-3-P - ELR H3-IS-PT- 24DC/500AC-3-P 2909570 PHOENIX CONTACT Hybrid motor starter as an alternative to a conventiona..
Kipatikana Bidhaa Maarufu

ELR H3-IS-PT-24DC/500AC-3-P

ELR H3-IS-PT- 24DC/500AC-3-P 2909570 PHOENIX CONTACT Hybrid motor starter as an alternative to a conventiona..

$0.00USD
3027 kwenye hisa
Vipimo Muhimu
GTIN:4055626426273
Ufunguo wa kuagiza:2909570
(Takwimu za UL):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
(Michoro):
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
GTIN4055626426273
Ufunguo wa kuagiza2909570
(Takwimu za UL)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
(Michoro)
Ukurasa wa katalogiPage 33 (C-5-2019)
Kitengo cha kufungasha1 pc
(Data ya kuingiza)3 A (AC-53a)
(Usambazaji wa kifaa)19.2 V (“1” signal)
Kina (Michoro)114 mm
Upana (Michoro)22.5 mm
Nchi ya asiliDE (Germany)
ETIM 2.0 (eCl@ss)EC001037
ETIM 3.0 (eCl@ss)EC001037
ETIM 4.0 (eCl@ss)EC001037
ETIM 5.0 (eCl@ss)EC001037
ETIM 6.0 (eCl@ss)EC001037
ETIM 7.0 (eCl@ss)EC001037
Urefu (Michoro)107.5 mm
(Data ya muunganisho 2)Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
China RoHS (UL data)Environmentally Friendly Use Period = 50
Nambari ya ushuru maalum85371098
Dokezo (Ugavi wa kifaa)The enable input is compatible with signals with blanking (semiconductor output signals with test pulse with max. 3 ms duration),unblanking pulses of max. 4 ms are tolerated without adversely affecting the safety function.
REACh SVHC (UL data)Lead 7439-92-1
(Hali ya mazingira)Reverse polarity protection
(Conformance/approvals)1.5 hp (277 V AC / 480 V AC)
Jina la matokeo (Data ya kuingiza)AC output
Jina la muunganisho (Jumla)Control circuits
Muda wa kupoeza (Data ya kuingiza)20 min. (for auto reset)
Jina la kuingiza (Usambazaji wa kifaa)Control input and enable input
Urefu wa kukatwa (Jumla)10 mm
Mbinu ya muunganisho (Jumla)Push-in connection
FLA (Conformance/approvals)3 A (480 V AC)
(Viwango na Kanuni)NRNT.E172140
Mkondo wa uvujaji (Data ya kuingiza)0 mA
Masafa ya mtandao mkuu (Data ya kuingiza)50/60 Hz
SCCR (Conformance/approvals)100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
eCl@ss 4.0 (Uainishaji)27021100
eCl@ss 4.1 (Uainishaji)27021100
eCl@ss 5.0 (Uainishaji)27024000
eCl@ss 5.1 (Uainishaji)27024000
eCl@ss 6.0 (Uainishaji)27024000
eCl@ss 7.0 (Uainishaji)27024002
eCl@ss 8.0 (Uainishaji)27024002
eCl@ss 9.0 (Uainishaji)27370905
(Sifa za insulation)IEC 61508
Urefu wa juu zaidi (Vipimo)≤ 2000 m
Insulation (Data ya muunganisho 2)Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Kumbuka (Towe la data ya pato)Confirmation: floating change-over contact, signal contact
Uteuzi (Data ya muunganisho 2)Isolation characteristics between the control input and control supply voltage to auxiliary circuit
Dalili (Kujikwaa kwa kasi kupita kiasi)Red LED
Pakia masafa ya sasa (Data ya kuingiza)180 mA ... 3 A
Kiwango cha ubadilishaji (Usambazaji wa kifaa)< 5 V DC (For EMERGENCY STOP)
Aina ya ulinzi (Data ya kuingiza)Surge protection
Jina la muunganisho (Data ya muunganisho)Load circuit
Kiwango cha ulinzi (Vipimo)IP20
Aina ya kupachika (Kuteleza kwa kasi kupita kiasi)DIN rail mounting
Urefu wa kuondoa (Data ya muunganisho)10 mm
Aina ya ulinzi (Ugavi wa kifaa)Reverse polarity protection
Mbinu ya muunganisho (Data ya muunganisho)Push-in connection
Hali ya uendeshaji (Kuteleza kwa kasi kupita kiasi)100% operating factor
Onyesho la hali (Kuteleza kwa kasi kupita kiasi)Yellow LED
Kizingiti cha kubadili (Usambazaji wa kifaa)9.6 V (“0” signal)
Kiwango cha volteji kinachofanya kazi (Data ya kuingiza)42 V AC ... 550 V AC
Uzito kwa Kipande (bila kujumuisha upakiaji)300.000 g
Category code (Conformance/approvals)NLDX / NRNT
Sehemu ya msalaba ya kondakta AWG (Jumla)24 ... 14
Jina la matokeo (Toweo la mzigo wa data ya matokeo)Acknowledge output
Muda wa kawaida wa kuzima (Usambazaji wa kifaa)< 30 ms
Aina ya mawasiliano (Towe la data ya pato)1 PDT
Nafasi ya kupachika (Kujikwaa kwa kasi kupita kiasi)vertical (horizontal DIN rail, motor output below)
Certificate (Standards and Regulations)NLDX.E228652
Sehemu ngumu ya kondakta (Jumla)0.2 mm² ... 2.5 mm²
Kiwango cha uchafuzi (Data ya muunganisho 2)2
Designation (Standards and Regulations)Category (ISO 13849)
Mkondo wa uendeshaji uliokadiriwa (Data ya kuingiza)3 A (AC-51)
Volti ya uendeshaji iliyokadiriwa Ue (Data ya kuingiza)500 V AC
Volti ya kuongezeka iliyokadiriwa (Data ya muunganisho 2)6 kV
Aina ya ulinzi (Hali ya mazingira)Surge protection
Uteuzi (Sifa za insulation)Standards/regulations
Kategoria ya volteji kupita kiasi (Data ya muunganisho 2)III
Muda wa majibu (Towe la majibu ya data)< 0.5 s
Masafa ya kubadili (Kujikwaa kwa kasi kupita kiasi)≤ 2 Hz (Load-dependent)
Kiwango cha volteji kinachosababisha (Ugavi wa kifaa)19.2 V DC ... 30 V DC
Maagizo ya usanidi (Kujikwaa kwa kasi kupita kiasi)alignable, for spacing see derating
Sehemu ya msalaba ya kondakta inayonyumbulika (Jumla)0.2 mm² ... 2.5 mm²
Group installation (Conformance/approvals)20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
Horsepower ratings (Conformance/approvals)0.5 hp (120 V AC / 208 V AC)
Identification (Standards and Regulations)≤ 3
IC ya sasa inayoendesha iliyokadiriwa (Ugavi wa kifaa)7 mA
UC ya volteji inayoamilishwa (Usambazaji wa kifaa)24 V DC
Additional text (Standards and Regulations)Safe shutdown
Halijoto ya mazingira (uendeshaji) (Vipimo)-25 °C ... 70 °C (observe derating)
Kizingiti cha uendeshaji (Towe la majibu ya data ya matokeo)> 33 A
Volti ya insulation iliyokadiriwa (Data ya muunganisho 2)550 V
Sehemu ya msalaba ya kondakta AWG (Data ya muunganisho)24 ... 14
Usambazaji wa nguvu wa kiwango cha juu (Kuteleza kwa kasi kupita kiasi)4.1 W
Usambazaji mdogo wa nguvu (Kuteleza kwa kasi kupita kiasi)0.88 W
Onyesho la volteji ya uendeshaji (Kuteleza kwa kasi kupita kiasi)Green LED
Sehemu ngumu ya kondakta (Data ya muunganisho)0.2 mm² ... 2.5 mm²
Kiwango cha volteji ya usambazaji wa udhibiti (Hali za mazingira)19.2 V DC ... 30 V DC
Sehemu ya msalaba ya kondakta inayonyumbulika (Data ya muunganisho)0.2 mm² ... 2.5 mm²
Viwango/kanuni (Sifa za insulation)EN 60947-1
Halijoto ya kawaida (uhifadhi/usafiri) (Vipimo)-40 °C ... 80 °C
Udhibiti uliokadiriwa wa usambazaji wa sasa wa IS (Hali za mazingira)60 mA
Ambient temperature (operation) (Conformance/approvals)-25 °C ... 55 °C
Volti ya usambazaji wa saketi ya udhibiti iliyokadiriwa Marekani (Hali za mazingira)24 V DC
Kipengele cha kichochezi katika acc. na IEC 60947-4-2 (Data ya kuingiza)Class 10
Uwezo wa kubadilisha kulingana na IEC 60947-5-1 (Towe la mzigo wa data ya pato)2 A (24 V, DC13)

Maelezo ya Bidhaa

Hybrid motor starter as an alternative to the classic protection circuit. It starts engines from 3~ AC up to 3 A, offers engine protection and emergency stop up to SIL 3 / PL e. Possibility of group d