| Kipengele | Thamani |
|---|---|
| GTIN | 4046356771375 |
| Ufunguo wa kuagiza | 2903914 |
| (Takwimu za UL) | Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC |
| Ukurasa wa katalogi | Page 30 (C-5-2017) |
| Kina (Dokezo) | 113.7 mm |
| Kitengo cha kufungasha | 1 pc |
| Upana (Dokezo) | 22.5 mm |
| (Data ya kuingiza) | 0.6 A (AC-53a) |
| Urefu (Dokezo) | 107.4 mm |
| (Usambazaji wa kifaa) | 19.2 V (“1” signal) |
| Nchi ya asili | DE (Germany) |
| (Data ya muunganisho 2) | 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) |
| Nambari ya ushuru maalum | 85371098 |
| Insulation (data ya UL) | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
| (Hali ya mazingira) | Reverse polarity protection |
| Uteuzi (data ya UL) | Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
| FLA (Data ya muunganisho 2) | 0.6 A (500 V AC) |
| Jina la matokeo (Data ya kuingiza) | AC output |
| SCCR (Data ya muunganisho 2) | 100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
| (Idhini/makubaliano) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Jina la muunganisho (Jumla) | Control circuits |
| Muda wa kupoeza (Data ya kuingiza) | 20 min. (for auto reset) |
| (Towe la mzigo wa data) | 2 A (24 V, DC13) |
| Jina la kuingiza (Usambazaji wa kifaa) | Control input |
| Dokezo (Data Muhimu ya Kibiashara) | If this device is to be used in combination with the CrossPowerSystem power distribution board, the device mount for the 16 A fuse (order designation: EM-CPS-DA-22,5F/16A; order number: 1002668) is required in order to attach the hybrid motor starter to the power distribution board. |
| Urefu wa kukatwa (Jumla) | 10 mm |
| Mbinu ya muunganisho (Jumla) | Push-in connection |
| (Viwango na Kanuni) | II (2) D [Ex t] [Ex p] |
| Mkondo wa uvujaji (Data ya kuingiza) | 0 mA |
| Masafa ya mtandao mkuu (Data ya kuingiza) | 50/60 Hz |
| (Sifa za insulation) | II (2) D [Ex t] [Ex p] |
| Kiwango cha uchafuzi (data ya UL) | 2 |
| Volti ya kuongezeka iliyokadiriwa (data ya UL) | 6 kV |
| Kumbuka (Towe la data ya pato) | Confirmation: floating change-over contact, signal contact |
| Kategoria ya volteji kupita kiasi (data ya UL) | III |
| Pakia masafa ya sasa (Data ya kuingiza) | 75 mA ... 600 mA (see to derating) |
| Kiwango cha ubadilishaji (Usambazaji wa kifaa) | < 5 V DC (For EMERGENCY STOP) |
| Aina ya ulinzi (Data ya kuingiza) | Surge protection |
| ATEX (Viwango na Kanuni) | II (2) G [Ex e] [Ex d] [Ex px] |
| ATEX (Sifa za insulation) | II (2) G [Ex e] [Ex d] [Ex px] |
| Msimbo wa kategoria (Data ya muunganisho 2) | NLDX |
| Kiwango cha ulinzi (Vipimo) | IP20 |
| Volti ya insulation iliyokadiriwa (data ya UL) | 500 V |
| Aina ya noti (Data Muhimu ya Biashara) | Notes on operation |
| Aina ya ulinzi (Ugavi wa kifaa) | Reverse polarity protection |
| RoHS ya China (Idhini/Uzingatiaji) | Environmentally Friendly Use Period = 50 |
| Jina la muunganisho (Data ya muunganisho 1) | Load circuit |
| Kizingiti cha kubadili (Usambazaji wa kifaa) | 9.6 V (“0” signal) |
| Kiwango cha volteji kinachofanya kazi (Data ya kuingiza) | 42 V AC ... 550 V AC |
| Urefu wa kuondoa (Data ya muunganisho 1) | 10 mm |
| Uzito kwa Kipande (bila kujumuisha upakiaji) | 217.700 g |
| Sehemu ya msalaba ya kondakta AWG (Jumla) | 24 ... 14 |
| Mbinu ya muunganisho (Data ya muunganisho 1) | Push-in connection |
| Dalili (Towe la majibu ya data ya matokeo) | Red LED |
| Jina la matokeo (Toweo la mzigo wa data ya matokeo) | Acknowledge output |
| Muda wa kawaida wa kuzima (Usambazaji wa kifaa) | < 30 ms |
| Aina ya mawasiliano (Towe la data ya pato) | 1 PDT |
| Usakinishaji wa kikundi (Data ya muunganisho 2) | 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) |
| Ukadiriaji wa nguvu za farasi (Data ya muunganisho 2) | - |
| Sehemu ngumu ya kondakta (Jumla) | 0.2 mm² ... 2.5 mm² |
| Mkondo wa uendeshaji uliokadiriwa (Data ya kuingiza) | 0.6 A (AC-51) |
| Volti ya uendeshaji iliyokadiriwa Ue (Data ya kuingiza) | 500 V AC |
| Aina ya ulinzi (Hali ya mazingira) | Surge protection |
| Uteuzi (Sifa za insulation) | Standards/regulations |
| Aina ya kupachika (Toweo la majibu ya data ya pato) | DIN rail mounting |
| Kiwango cha volteji kinachosababisha (Ugavi wa kifaa) | 19.2 V DC ... 30 V DC |
| Hali ya uendeshaji (Towe la majibu ya data) | 100% operating factor |
| Onyesho la hali (Towe la majibu ya data ya matokeo) | Yellow LED |
| Sehemu ya msalaba ya kondakta inayonyumbulika (Jumla) | 0.2 mm² ... 2.5 mm² |
| IC ya sasa inayoendesha iliyokadiriwa (Ugavi wa kifaa) | 5 mA (Input type 1) |
| UC ya volteji inayoamilishwa (Usambazaji wa kifaa) | 24 V DC |
| Cheti cha UL (Viwango na Kanuni) | NLDX.E228652 |
| Halijoto ya mazingira (uendeshaji) (Vipimo) | -25 °C ... 70 °C (observe derating) |
| Nafasi ya kupachika (Toweo la majibu ya data ya pato) | vertical (horizontal DIN rail, motor output below) |
| Masafa ya kubadilisha (Towe la majibu ya data ya kutoa) | ≤ 2 Hz (Load-dependent) |
| Sehemu ya msalaba ya kondakta AWG (Data ya muunganisho 1) | 24 ... 14 |
| Maagizo ya uunganishaji (Toweo la majibu ya data ya matokeo) | alignable, for spacing see derating |
| Sehemu ngumu ya kondakta (Data ya muunganisho 1) | 0.2 mm² ... 2.5 mm² |
| Kiwango cha volteji ya usambazaji wa udhibiti (Hali za mazingira) | 19.2 V DC ... 30 V DC |
| Viwango/kanuni (Sifa za insulation) | IEC 60947-1 |
| Halijoto ya kawaida (uhifadhi/usafiri) (Vipimo) | -40 °C ... 80 °C |
| Sehemu ya msalaba ya kondakta inayonyumbulika (Data ya muunganisho 1) | 0.2 mm² ... 2.5 mm² |
| Usambazaji wa nguvu ya juu zaidi (Towe la majibu ya data ya pato) | 1.5 W |
| Usambazaji mdogo wa nguvu (Towe data reply output) | 1.1 W |
| Onyesho la volteji ya uendeshaji (Towe la majibu ya data ya pato) | Green LED |
| Udhibiti uliokadiriwa wa usambazaji wa sasa wa IS (Hali za mazingira) | 40 mA |
| Kukubalika kwa kategoria kwa EN ISO 13849 (Viwango na Kanuni) | ≤ 3 (Safe shutdown) |
| Cheti cha mtihani wa aina ya EU (Viwango na Kanuni) | PTB 07 ATEX 3145 |
| Volti ya usambazaji wa saketi ya udhibiti iliyokadiriwa Marekani (Hali za mazingira) | 24 V DC |
| Kipengele cha kichochezi katika acc. na IEC 60947-4-2 (Data ya kuingiza) | Class 10A |
| Kiwango cha utendaji kulingana na ISO 13849 (Viwango na Kanuni) | ≤ e (Safe shutdown) |
| Uwezo wa kubadilisha kulingana na IEC 60947-5-1 (Towe la mzigo wa data ya pato) | 3 A (230 V, AC15) |
| Kiwango cha Uadilifu wa Usalama kulingana na IEC 61508 (Viwango na Kanuni) | ≤ 3 (Safe shutdown) |
Speci za kiufundi na data ya utendaji