Muda wa huduma: Jumatatu hadi Ijumaa 9:00-18:00
CPTDINAV61LS2BX - CPTDINAV61LS2BX CARLO GAVAZZI Selected parameters FUNCTION Transducers MOUNTING DIN Rail POWER SUPPLY 18 to ..
Kipatikana Bidhaa Maarufu

CPTDINAV61LS2BX

CPTDINAV61LS2BX CARLO GAVAZZI Selected parameters FUNCTION Transducers MOUNTING DIN Rail POWER SUPPLY 18 to ..

$0.00USD
4133 kwenye hisa
Taarifa za Msambazaji
CARLO GAVAZZI
CARLO GAVAZZI
Bidhaa: 10094
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Maelezo ya Bidhaa

Compact three-phase power transducer, Din rail, basic version
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Maelezo ya Kiufundi

Energy Management Compact Power Transducer Type CPT-DIN “Basic version”• RS232 serial port on request• Alarms (only from serial communication port) VLN, An• Class 2 (active energy)• Class 3 (reactive energy)• Accuracy ±0.5 F.S. (current/voltage)• Compact Power transducer• Instantaneous variables data format: 4 digit• Energies data format: 8+1 digit• System variables and phase measurements: W, Wdmd, Wdmdmax, var, VA, VAdmd, PF, V, A, An, Admd, Amax, Admd max, Hz• Energy measurements: kWh and kvarh• Hour counter (5+2 DGT)• TRMS meas. of distorted sine waves (voltages/currents)• Power supply: 90 to 260VAC/DC and 18 to 60VAC/DC• Protection degree (front): IP20• Dimensions: 45x83.5x98.5mm• RS422/485 serial portProduct DescriptionHow to order CPT-DIN AV5 3 HS1 BX3-phase compact power transducer. Particularly rec- ommended for the measure- ments of the main electrical variables.Housing for DIN-rail mount-ing, protection degree IP20 as standard, and RS485 or RS232 serial port. Parameters programmable by means of CptBSoft.Model Range code SystemPower supply Outputs OptionHow to orderCptBSoft-kitType SelectionCptBSoft: software to program the working parameters of the transducer and to read the energy and the instanta- neous variables. The kit includes the communication cable.Range codesAV5: 400/(690)VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 VAV6: 120/(208)VL-L/5(6)AAC VL-N: 45 V to 145 VVL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6ASystem3 :1, 2 or 3-phase, unbalanced and balanced load, with or without neutral1 :1-3-phase, balanced load (*)Power supplyL: 18 to 60VAC/DCH: 90 to 260VAC/DC(*)Pay attention:the 3-phase measurement is carried out as one current and one phase to neutral voltage measurement.OutputsS1: RS485 portS2: RS232 portOptionsBX: Basic featuresInputspecificationsRated inputsCurrent3 (current transformers) Voltage4Accuracy (RS485/RS232)with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%)1150W-VA-var, FS:230VLN,400VLL AV6: 285W-VA-var, FS: 57VLN, 100VLLCurrent 0.25 to 6A: ±(0.5% FS +1DGT)0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current0.25 to 6A: ±(1.5% FS +1DGT)0.09Ato0.25A:±(1.5%FS+7DGT)Phase-phase voltage ±(1.5% FS + 1DGT) Phase-neutral voltage ±(0.5% FS + 0.1DGT) Active and Apparent power,0.25 to 6A: ±(1%FS +1DGT)0.03A to 0.25A: ±(1%FS+5DGT)Reactive power 0.25 to 6A: ±(2% FS +1DGT)0.03A to 0.25A: ±(2% FS +5DGT) Active energy Class 2 (I start up: 30mA) Reactive energyClass 3 (I start up: 30mA) Frequency±0.1Hz (48 to 62Hz)Additional errorsHumidity≤0.3% FS, 60% to 90% RHTemperature drift≤ 200ppm/°CSampling rate1400 samples/s @ 50Hz1700 samples/s @ 60HzMeasurement refresh time 700msMeasurement formatInstantaneous variables4 DGT (Max indication: 9999) Energies 9 DGT (Max indication:999 999 99.9)Hour counter 7 DGT (Max. indication:9 999 9.99)Specifications are subject to change without noticeCPT-DINBDS080610 1

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji