Muda wa huduma: Jumatatu hadi Ijumaa 9:00-18:00
CLOUD IOT GATEWAY - CLOUD IOT GATEWAY 1031235 PHOENIX CONTACT IoT gateway
Kipatikana Bidhaa Maarufu

CLOUD IOT GATEWAY

CLOUD IOT GATEWAY 1031235 PHOENIX CONTACT IoT gateway

$0.00USD
3148 kwenye hisa
Vipimo Muhimu
GTIN:4055626534169
Dokezo:Made to Order (non-returnable)
Ufunguo wa kuagiza:1031235
Kitengo cha kufungasha:1 pc
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
GTIN4055626534169
DokezoMade to Order (non-returnable)
Ufunguo wa kuagiza1031235
Kitengo cha kufungasha1 pc
Nchi ya asiliDE (Germany)
Mshtuko (Vipimo)30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Nambari ya ushuru maalum85176200
Kichakataji (Ugavi wa umeme)ARM®Cortex®-A8 1x 600 MHz
Nambari (Ubunifu wa mitambo)1
Kina (Data Muhimu ya Biashara)114.5 mm
Uzito (Hali ya mazingira)144.5 g
Upana (Data Muhimu ya Biashara)22.5 mm
(Viwango na Kanuni)No hazardous substances above threshold values
Urefu (Data Muhimu ya Kibiashara)99 mm
Kiolesura (Ubunifu wa mitambo)Service
Saa ya muda halisi (Data ya jumla)Yes
Mshtuko (mfumo wa muda wa IEC 61131)30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Volti ya usambazaji (Violesura vya data)24 V DC -20 % / +15 %
Kiwango cha ulinzi (Vipimo)IP20
Uzito kwa Kipande (bila kujumuisha upakiaji)144.500 g
Shinikizo la hewa (uendeshaji) (Vipimo)70 kPa ... 106 kPa (up to 3000 m above sea level)
Njia ya muunganisho (Ubunifu wa mitambo)USB type C
RoHS ya China (Viwango na Kanuni)Environmentally friendly use period: unlimited = EFUP-e
Kiwango cha volteji ya usambazaji (Violesura vya data)18 V DC ... 30 V DC
Kasi ya upitishaji (Ubunifu wa mitambo)100 Mbps
Kinga dhidi ya EF (mfumo wa muda wa IEC 61131)Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Kinga dhidi ya ESD (mfumo wa muda wa IEC 61131)Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Halijoto ya mazingira (uendeshaji) (Vipimo)-25 °C ... 55 °C up to 2000 m above mean sea level
Kinga ya kupasuka (mfumo wa muda wa IEC 61131)Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Kinga dhidi ya kuongezeka kwa kasi (mfumo wa muda wa IEC 61131)Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Mshtuko (uendeshaji) (mfumo wa muda wa IEC 61131)10g (Bump endurance test according to EN 60068-2-29)
Shinikizo la hewa (uhifadhi/usafiri) (Vipimo)58 kPa ... 106 kPa (up to 4500 m above mean sea level)
Unyevu unaoruhusiwa (uendeshaji) (Vipimo)30 % ... 95 % (according to DIN EN 61131-2)
Matumizi ya kawaida ya sasa (Violesura vya data)200 mA
Utoaji wa kuingiliwa (mfumo wa muda wa IEC 61131)Noise emission test according to EN 61000-6-3 Class B
Dokezo kuhusu vipimo vya uzito (Hali ya mazingira)with connectors
Halijoto ya kawaida (uhifadhi/usafiri) (Vipimo)-25 °C ... 85 °C
Unyevu unaoruhusiwa (uhifadhi/usafiri) (Vipimo)5 % ... 95 %
Utangamano wa sumaku-umeme (mfumo wa muda wa IEC 61131)Conformance with EMC Directive 2014/30/EU
Kinga dhidi ya kuingiliwa kunakofanywa (mfumo wa muda wa IEC 61131)Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V

Maelezo ya Bidhaa

Cloud IoT gateway for integration of new and existing installations without additional engineering tasks. By easily integrating processes with protocols such as Modbus/TCP, sensor and process data are
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji