Muda wa huduma: Jumatatu hadi Ijumaa 9:00-18:00
AXC CLOUD-PRO - AXC CLOUD-PRO 2402985 PHOENIX CONTACT Controller
Kipatikana Bidhaa Maarufu

AXC CLOUD-PRO

AXC CLOUD-PRO 2402985 PHOENIX CONTACT Controller

$0.00USD
3535 kwenye hisa
Vipimo Muhimu
GTIN:4055626231150
Dokezo:Made to Order (non-returnable)
Ufunguo wa kuagiza:2402985
Ukurasa wa katalogi:Page 7 (C-6-2017)
Taarifa za Msambazaji
Bidhaa: 0
Kwa kawaida husafirisha ndani ya siku 2-3 za kazi
Ubora Umeheshimiwa
Usafirishaji wa haraka
Msaada wa Kiufundi

Speci ya Kiufundi

KipengeleThamani
GTIN4055626231150
DokezoMade to Order (non-returnable)
Ufunguo wa kuagiza2402985
Ukurasa wa katalogiPage 7 (C-6-2017)
Kitengo cha kufungasha1 pc
Nchi ya asiliDE (Germany)
Mshtuko (Vipimo)25g, Criterion 1, according to IEC 60068-2-27
Nambari ya ushuru maalum85371098
Uzito (Mfumo wa Udhibiti)225.6 g
Nambari (Ubunifu wa mitambo)2
Kina (Data Muhimu ya Biashara)74 mm
Hifadhi ya wingi (Data ya jumla)1 Mbyte
Upana (Data Muhimu ya Biashara)45 mm
(Viwango na Kanuni)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Urefu (Data Muhimu ya Kibiashara)125.9 mm
Kiolesura (Ubunifu wa mitambo)Ethernet
Kichakataji (kazi ya Fieldbus)Altera Nios II 100 MHz
Kumbukumbu ya programu (Data ya jumla)1 Mbyte
Saa ya muda halisi (Data ya jumla)Yes
Zana ya uhandisi (Data ya jumla)PC WORX
Kipengele cha usalama (Mfumo wa udhibiti)No
Mshtuko (mfumo wa muda wa IEC 61131)25g, Criterion 1, according to IEC 60068-2-27
Volti ya usambazaji (Violesura vya data)24 V DC
Kiwango cha ulinzi (Vipimo)IP20
Mawimbi ya mabaki (Violesura vya data)± 5 %
Mtetemo (uendeshaji) (Vipimo)5g
Usambazaji wa nguvu (Violesura vya data)max. 3 W
Onyesho la uchunguzi (Mfumo wa kudhibiti)No
Uzito kwa Kipande (bila kujumuisha upakiaji)246.300 g
Shinikizo la hewa (uendeshaji) (Vipimo)70 kPa ... 106 kPa (up to 3000 m above sea level)
Njia ya muunganisho (Ubunifu wa mitambo)RJ45 socket
Zana ya uhandisi (Hali ya mazingira)PC WORX
Hifadhi ya wingi iliyohifadhiwa (Data ya jumla)48 kByte (NVRAM)
RoHS ya China (Viwango na Kanuni)Environmentally Friendly Use Period = 50
Upungufu wa vidhibiti (Mfumo wa udhibiti)No
Idadi ya kazi za udhibiti (Data ya jumla)8
Kiwango cha volteji ya usambazaji (Violesura vya data)19.2 V DC ... 30 V DC
Kasi ya upitishaji (Ubunifu wa mitambo)10/100 Mbps
Utoaji wa kelele (mfumo wa muda wa IEC 61131)EN 61000-6-4
Kinga ya kelele (mfumo wa muda wa IEC 61131)Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 EN 61000-4-3 (radiated noise immunity) Criterion A, 10 V/m
Kinga dhidi ya ESD (mfumo wa muda wa IEC 61131)Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 EN 61000-4-2 (ESD) Criterion B, 6 kV contact discharge, 8 kV air discharge
Matumizi ya juu zaidi ya sasa (Violesura vya data)160 mA
Idadi ya vifaa vinavyotumika (Usambazaji wa umeme)max. 63
Halijoto ya mazingira (uendeshaji) (Vipimo)-25 °C ... 60 °C
Kinga ya kupasuka (mfumo wa muda wa IEC 61131)Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 EN 61000-4-4 (EFT burst) Criterion B; Supply lines: 2 kV; Signal/data lines: 2 kV
Kinga dhidi ya kuongezeka kwa kasi (mfumo wa muda wa IEC 61131)Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 EN 61000-4-5 (surge) Criterion B
Mshtuko (uendeshaji) (mfumo wa muda wa IEC 61131)10g (Bump endurance test according to DIN EN 60068-2-27)
Shinikizo la hewa (uhifadhi/usafiri) (Vipimo)70 kPa ... 106 kPa (up to 3000 m above sea level)
Unyevu unaoruhusiwa (uendeshaji) (Vipimo)10 % ... 95 % (according to DIN EN 61131-2)
Matumizi ya kawaida ya sasa (Violesura vya data)125 mA
Utoaji wa kuingiliwa (mfumo wa muda wa IEC 61131)Noise emission test as per EN 61000-6-4 EN 55011 (emitted interference) Class A
Mtetemo (uendeshaji) (mfumo wa muda wa IEC 61131)5g
Halijoto ya kawaida (uhifadhi/usafiri) (Vipimo)-40 °C ... 85 °C
Lugha za programu zinazotumika (Hali za mazingira)Programming in acc. with IEC 61131-3
Unyevu unaoruhusiwa (uhifadhi/usafiri) (Vipimo)10 % ... 95 % (according to DIN EN 61131-2)
Utangamano wa sumaku-umeme (mfumo wa muda wa IEC 61131)Conformance with EMC Directive 2014/30/EU
Mtetemo (uhifadhi/usafiri) (mfumo wa muda wa IEC 61131)5g
Kinga dhidi ya kuingiliwa kunakofanywa (mfumo wa muda wa IEC 61131)Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 EN 61000-4-6 (line noise immunity) Criterion A; Test voltage 10 V

Maelezo ya Bidhaa

Axiocontrol for communication with PROFICLOUD. For direct control of Axioline I/O. With 2 Ethernet interfaces and programmability in accordance with IEC 61131-3. Complete with connection connector and
Vipengele Muhimu
  • Ubora wa kiwango cha viwanda
  • Inaendana na RoHS
  • Imethibitishwa CE
  • Dhamana ya mwaka 1

Nyaraka za Bidhaa

Jalada la data

Speci za kiufundi na data ya utendaji

Mwongozo wa Mtumiaji

Mwongozo wa usakinishaji na uendeshaji