| Kipengele | Thamani |
|---|---|
| Bidhaa | FP7 High-speed Counter Units |
| Nambari ya Sehemu | AFP7HSC4T |
| Jina la bidhaa | FP7 High-speed Counter |
| Nambari ya Bidhaa | AFP7HSC4T |
| Ingizo: Njia ya insulation | Photocoupler insulation |
| Ingizo: Volti ya kuingiza iliyokadiriwa | 12 to 24 V DC / 3.5 to 5 V DC |
| Kitendakazi cha hesabu: Aina ya kaunta | Linear counter / Ring counter |
| Kitendakazi cha hesabu: I/O ya Nje | Control signal input: 8 points (2 points/ch), External output: 8 points (2 points/ch) |
| Kitendakazi cha hesabu: Ishara ya kuingiza | Phases A, B and Z |
| Ingizo: Impedans ya Ingizo: 5 V DC | 390 Ohm (5 V DC) approx. |
| Kitendakazi cha kuhesabu: Kipindi cha kuhesabu | Signed 32-bit (-2,147,483,648 to +2,147,483,647) |
| Ingizo: Impedans ya Ingizo: 24 V DC | 3.0 kOhm approx. |
| Kitendakazi cha hesabu: Idadi ya vihesabu | 4ch |
| Ingizo: Kiwango cha volteji ya matumizi: 5 V DC | 3.5 to 5.25 V DC |
| Kazi zingine: Kipengele cha kunasa | Acquires the current count value from the edges of input signals, and stores it in the capture 0 register or capture 1 register. The value of the specified capture register will be overwritten by a new value and the old value will be discarded every time a counter value is captured. |
| Kitendakazi cha hesabu: Aina ya ingizo la kaunta | Individual input (Phases A and B): 1 multiple, 2-multipleDirection discrimination input: 1 multiple, 2-multiple2-phase input: 1 multiple, 2-multiple, 4-multiple |
| Ingizo: Mpangilio wa muda usiobadilika | None, 0.1 micro s, 0.2 micro s, 0.5 micro s, 1.0 micro s, 2.0 micro s and 10.0 micro s |
| Ingizo: Kiwango cha volteji ya matumizi: 24 V DC | 10.8 to 26.4 V DC |
| Kitendakazi cha hesabu: Masafa ya juu zaidi ya kuingiza | 4 MHz / 8 MHz for individual input (phases A and B) (Duty ratio 50 plus or minus 10 %), 4 MHz / 8 MHz for direction discrimination input (Duty ratio 50 plus or minus 10 %), 4 MHz / 8 MHz /16 MHz for 2-phase input (Duty ratio 50 plus or minus 10 %, Phase shifting below 5 %) |
| Kazi zingine: Kipengele cha kuingiza sauti cha kukatiza | Available (2 points/ch, Max. 8 points/unit)(Note) The interrupt input function can be used for 8 points per unit and for a maximum of 8 units (max. 64 points) in the whole system. However, the entire scan time slows down as more interrupt programs are used. Minimize the use of interrupt programs.(Note) The priority order for interrupt inputs is as follows; In a unit, from the smallest interrupt bit. In the whole system, from the smallest unit number. |
| Ingizo:Voliti ya chini kabisa ya ON / Mkondo wa chini kabisa wa ON: 5 V DC | 3.0 V DC / 4 mA |
| Kitendakazi cha kulinganisha: Kitendakazi cha kulinganisha thamani lengwa | Depending on the count direction, sets or resets the output when the counter value reaches the target value. |
| Ingizo: Volti ya chini kabisa kwenye ON / Kiwango cha chini kabisa cha ON: 24 V DC | 10 V DC / 4 mA |
| Ingizo: Volti ya juu kabisa ya KUZIMA / Mkondo wa juu kabisa wa KUZIMA: 5 V DC | 1.0 V DC / 0.5 mA |
| Matokeo ya nje: Kitendakazi cha matokeo ya kulinganisha | Outputs the result of comparison function. |
| Ingizo: Volti ya Juu kabisa ya KUZIMA / Mkondo wa Juu kabisa wa KUZIMA: 24 V DC | 2.0 V DC / 2 mA |
| Kipengele cha kipimo: Kipengele cha kipimo cha masafa | Measures the intervals between the variations of count values, and calculates the frequency. |
Speci za kiufundi na data ya utendaji
Mwongozo wa usakinishaji na uendeshaji